Remote-A Or B Selection; Hi-Power Mode - Toshiba RAS-B07J2KVSG-E Service Manual

Split type
Hide thumbs Also See for RAS-B07J2KVSG-E:
Table of Contents

Advertisement

Item
15. Remote-A or B
Setting the remote controller
selection
To separate using of remote control for each indoor
unit in case of 2 air conditioner are installed nearly.
Remote Control B Setup.
1) Press [RESET] button on the indoor unit to turn
the air conditioner ON.
2) Point the remote control at the indoor unit.
3) Push and hold [CHECK] button on the Remote
Control by the tip of the pencil. "00" will be shown
shown on the display (Picture
4) Press [MODE] during pushing [CHECK]."B" will
show on the display and "00" will disappear and
the air conditioner will turn OFF. The Remote
Control B is memorized (Picture
Note : 1. Repeat above step to reset Remote Control
16. Hi-POWER
([Hi-POWER] button on the remote controller
Mode
is pressed)
When [Hi-POWER] button is pressed while the indoor
unit is in Auto, Cooling or Heating operation, Hi-
POWER mark is indicated on the display of the remote
controller and the unit operates as follows.
1. Automatic operation
• The indoor unit operates in according to the
current operation.
2. Cooling operation
• The preset temperature drops 1ºC
(The value of the preset temperature on the
remote controller does not change.)
The indoor unit's fan speed level increase 1 tap
3. Heating operation
• The preset temperature increases 2ºC
(The value of the preset temperature on the
remote controller does not change.)
The indoor unit's fan speed level increase 1 tap
4. The Hi-POWER mode can not be set in Dry
operation
Operation flow and applicable data, etc.
to be A.
2. Remote Control A has not "A" display.
3. Default setting of Remote Control from
factory is A.
1
1. Purpose
This operation is to operate only one
indoor unit using one remote controller.
2. Description
When operating one indoor unit in a
situation where two indoor units have
been installed in the same room or
nearby rooms, this operation prevents
the remote controller signal from being
received simultaneously by both units,
).
1
thus preventing both units from
operating.
3. Operation
The indoor unit on which the remote
).
2
controller selection has been set to B
receives the signal of the remote control-
ler also set to B.
(At the factory the remote controller
selection is set to A on all the indoor
units. There is no A setting display.)
2
- 48 -