Toshiba RAS-B07J2KVSG-E Service Manual page 115

Split type
Hide thumbs Also See for RAS-B07J2KVSG-E:
Table of Contents

Advertisement

No.
Part name
Vertical louver
1) Follow the procedure item 3 and 7 .
8
assembly
2) Remove 2 fixing screws from the base vertical
9
Cross flow fan
1) Follow the procedure item 3 and 4 .
2) Loosen the set screw of the cross flow fan.
3) Remove 4 fixing screws from the bearing
Procedures
louver then remove the vertical louver
assembly from the body back.
base then remove it from the main unit.
4) Lift up the heat exchanger follow the figure.
Pull out the left hand side until the cross flow
fan is released from the shaft of the fan
motor and then pull out the lower side of
heat exchanger follow the figure.
<To re-installation>
1) To incorporate the fan motor and the
motor into the position in the following
figure.
- Install the cross flow fan so that the right
end of the 1st joint from the right of the
Cross flow fan is keep 3.5mm from
closed wall of the main unit.
Cross flow fan
3.5 mm
Set screw
- Holding the set screw, install the
cross flow fan so that flat area on shaft of
the fan motor comes to the mounting hole
of the set screw.
Body back
Fan motor
- 115 -
Remarks
Vertical
louver
Screw
Heat exchanger
Bearing base
Cross flow fan
Heat exchanger
Cross flow fan
Screw