P/N : 002-00038-00 INSTALLATION AND SAFETY MANUAL FOR TIGO ENERGY® MODULE MAXIMIZER™ ES, 2ES, J-ES CONTACT US: 420 Blossom Hill Road +1.888.681.TIGO (8446) +1.408.358.6279 Los Gatos, CA 95032, USA Customer support fax Fax outside the USA (toll-free in USA) +1.888.609.TIGO (8446) Support@tigoenergy.com...
Page 2
Do not attempt to install in inclement weather. • Risk of electric shock, do not remove cover, disassemble, or • Do not operate the Tigo Energy Module Maximizer if it has repair, no user serviceable parts inside. Refer servicing to quali- been physically damaged.
TABLE OF CONTENTS: 1. System Overview 2. Installing Management Unit 3. Installing Gateways (GTWY) 4. Mapping (MMU) DISCOVER MENU ENTER Internet Internet DISCOVER MENU ENTER 5. Configuring the 6. Installing Maximizers 7. Initiating Discovery 8. Connecting Modbus System Online Accessories (optional) DISCOVER MENU ENTER...
Optimizer: 1 MM-ES per 1 PV module 1 MM-2ES per 2 PV modules Module Maximizer - ES GTWY Installing Gateways-GTWY Internet Management Unit Smart Module - J-ES Max 95” (241 cm) 2ES - ST Tigo EnergyÆ Software Suite for Monitoring & Advanced Management Max 150” (380 cm) 2ES - XL Dual Module Maximizer - 2ES...
7.36” (18.7cm) WHERE TO PLACE? 8.05” (20.5cm) all or ear iNverter 2. Control 2.1. Discover MENU 2.2. Panels ON 2.5. GTWY Test Tigo Energy PV-SAFE 3. Network 3.2. Test Inverter Move 3.6 Renew Back Forward Plug in terminal after all...
3. INSTALLING GATEWAYS (GTWY) Place on back of PV module 3/8” (0.952cm) Racking system Run a wire from the MMU to the first GTWY In center of sub -array Last GTWYs or single GTWY installation Sub-array 1 (back) Sub-array 2 Last Sub-array GTWY Connection to next...
Page 7
MAC ID A1 Sticker Here Plan where to place Maximizers Need help? Call us today: North America: 1.888.609.TIGO (8446), International: 00800.CALL.TIGO (2255.8446) For 2ES installation: * Note that MM-2ES Dual Maxi- mizers will have a single label for two modules.
Page 8
5. CONFIGURING SYSTEM ONLINE https://installations.tigoenergy.com/ Option 1 New User Returning Option 2 User Click on Follow wizard instructions...
Page 9
Maximizer placement Need help? Call us today: North America: 1.888.609.TIGO (8446), International: 00800.CALL.TIGO (2255.8446) When using 2ES Dual Maximizers on an odd-length The shortest pair of input leads should be string, connect the medium length input cables of connected to the first panel of each pair.
7. INITIATING DISCOVERY MENU For systems with multiple Management Units (MMU) initiate discov- ery one by one, ensuring that GTWY discovery is complete before Press “Enter” moving to the next MMU. **Main Menu** This may take several minutes to several hours depending on the ENTER size of the system.
DATA Tigo Energy PV-SAFE AC meter Accessories Gateway Terminal Terminal inverter installation manual TIGO ENERGY SUPPORT GTWY +1.888.609.TIGO (8446) Modbus Modbus Device A Device B Recommended settings: • 9600 baud rate • 8 bits data Series connection for • 1 stop bit •...
Page 12
2ES Standard Length 2ES XL length 39.37” 51.18” 82.68” TYCO SOLARLOCK - Tigo positive input accepts Tyco male (+) or neutral keying. Tigo Connector negative input accepts female (+) or (-) keying. Do not connect any other type. Environmental Specifications Operating tempera- -30°C to + 70°C...