Problem solving guide
Problem
There is a film of oil on
the glass lid and in the
drawer.
The vacuuming process
is cancelled after
2 minutes. A signal
sounds and the
symbol lights up red.
The vacuuming process
is cancelled after
5 seconds. A signal
sounds and the
symbol lights up red.
36
Possible cause and remedy
The oil in the vacuum pump has become extremely
hot.
Clean the drawer and leave it to cool down for
1 hour before starting another vacuuming process.
When carrying out a number of consecutive
vacuuming processes, wait a minimum of
2 minutes between each process to prevent the oil
from overheating again.
If the problem occurs again, contact Miele.
The required final vacuum could not be achieved.
Switch the drawer off and back on again.
Start the vacuuming process again with lower
vacuum settings if necessary.
After intensive use of the drawer, the oil in the
vacuum pump has become extremely hot.
Leave the drawer to cool for an hour before
starting another vacuuming process.
When carrying out a number of consecutive
vacuuming processes, wait for at least 2 minutes
between each process. This prevents the oil from
overheating.
The glass lid is not sitting evenly. There is an object,
such as the edge of a bag or some soiling, on the
surface of the chamber seal.
Remove the obstruction and/or the soiling.
Close the glass lid and press it down lightly for
approx. 5 seconds.
The chamber seal is not fitted correctly.
Press the chamber seal in all the way round to
make sure it is fitted evenly.
The chamber seal is damaged, e.g. cracks can be
seen.
Call Miele to have it replaced.