Hardware installation
4.2 Installing hardware
To install and connect up the CP 5603 follow the steps outlined below:
1. Shut down your PC and disconnected it from the power supply.
2. Open the extension box as described in the manual of the mEC.
3. Set the module address on the CP 5603 as described in chapter 4.
4. Insert the CP 5603 into the prepared PCI-104 slot. Make sure that the CP 5603 sits firmly
and uniformly.
5. Take the 4 supplied M3, 15 mm spacing bolts, wrench size 5 mm and screw the CP 5603
to the underlying spacing bolts.
6. Replace the shelf of the extension box with the shelf for the CP 5603.
7. Screw the active RS-485 module to the shelf of the modular Embedded Controller. To do
this use the supplied locking bolts, 4-40 UNC, 8 mm, wrench size 4.5 mm.
8. Open the extension box as described in the manual of the mEC.
9. Insert the PROFIBUS cable into the corresponding PROFIBUS socket of the active RS-
485 module.
10.Connect the controller to the power supply again and restart the computer.
Marking
Position of the markings
20
Operating Instructions, 08/2016, A5E02146341A-04
CP 5603