C300HD Installation Guide
Phase Scope
Location:
Connector Type:
pin
Description
1
Circuit 1
14
Circuit 1
2
n/c
15
Circuit 2
3
Circuit 2
16
n/c
4
Circuit 3
17
Circuit 3
5
n/c
18
Circuit 4
6
Circuit 4
19
n/c
7
Circuit 5
20
Circuit 5
8
n/c
21
Circuit 6
9
Circuit 6
22
n/c
10
Circuit 7
23
Circuit 7
11
n/c
24
Circuit 8
12
Circuit 8
25
n/c
13
n/c
* Output circuits are looped through from the corresponding input within the RTW meter.
Phase Scope
Location:
Connector Type:
pin
1
6
2
7
3
8
4
9
5
Note. Connectors only fitted if a phasescope is specified.
Refer to manufacturer's own manual for diagnostic information and operating instructions.
Page 54
(Digital Circuits)
Audio connector panel
25-way D-type female
Notes: MSD600
+
AES/EBU in 1/2
-
+
AES/EBU in 3/4
-
+
AES/EBU in 5/6
-
+
unused
-
+
unused
-
+
unused
-
+
unused
-
+
unused
-
(Diagnostics and Control)
Audio connector panel
9-way D-type female
Notes: MSD600
Chassis
n/c
Rx Data
n/c
Tx Data
n/c
n/c
n/c
n/c
Notes: RTW10830
AES/EBU out 7/8*
AES/EBU out 5/6*
AES/EBU out 3/4*
AES/EBU out 1/2*
AES/EBU in 7/8
AES/EBU in 5/6
AES/EBU in 3/4
AES/EBU in 1/2
Notes: RTW10830
Switch common
Mode
Select
Memo
Gain
Reset
Shift
n/c
n/c