Summary of Contents for JENCO VisionPlus EC 330

  • Page 1 Operation Manual MODEL EC 330 Microcomputer Based Conductivity /TDS &Temperature Pocket Meter EC330...
  • Page 2: Table Of Contents

    CONTENTS INITIAL INSPECTION AND ASSEMBLY .....2 VISIONPLUS EC 330 OVERVIEW........2 ..........2 Meter Description ............2 B. LCD Display OPERATION MODES AND KEYPAD OPERATIONS...3 .............3 Operation Modes ..........3 Keypad Operations BEFORE YOUR FIRST USE ......…………4 ...........4 Insert Batteries ..........4 Soak the Electrode .........4...
  • Page 3: Initial Inspection And Assembly

    INITIAL INSPECTION AND ASSEMBLY Carefully unpack the instrument and accessories. Inspect for damages made in shipment. If any damage is found, notify your Jenco representative immediately. All packing materials should be saved until satisfactory operation is confirmed. VISIONPLUS EC 330 OVERVIEW A.
  • Page 4: Operation Modes And Keypad Operations

    9. TEMPERATURE unit indicator OPERATION MODES AND KEYPAD OPERATIONS A. Operation Modes VisionPlus EC 330 meter has 3 operation modes: Measure Mode. Measure Mode is used to make all conductivity or TDS and temperature measurements. Calibration Mode. Calibration Mode is used to perform 1 or 2 point calibration.
  • Page 5: Before Your First Use

    (included) ensuring correct polarities. Securely replace battery cover. B. Soak the Electrode Remove the electrode cap covering the VisionPlus EC 330 meter. Soak the electrode in distilled water for 10 minutes before first use or after storage. C. Preparing Standard Solutions Suitable conductivity standards are available commercially or the user can prepare them using research grade reagents.
  • Page 6: Setup And Calibrate The Electrode And Meter

    D. Setup and Calibrate the Electrode and Meter VisionPlus EC 330 must be setup and calibrated before your first use. Please follow the instructions detailed in section USING VISIONPLUS EC 330 USING VISIONPLUS EC 330 A. Power On/Off Press the “On/Off ” key to turn the unit on. If the unit is running then you can press the ”On/Off “...
  • Page 7: Measure

    Insert a new electrode, make sure the electrode fit back into the meter correctly. Screw back the electrode collar. Soak the electrode in distilled water for 10 minutes and recalibrate the EC 330 following the instructions detailed USING VISIONPLUS EC 330.. in section...
  • Page 8: Replace The Old Batteries

    REPLACE THE OLD BATTERIES Replace the battery when the blinking low battery indicator “ ” appears on the upper left corner of the LCD screen. The instrument can operate within specifications for approximately 2~3 hours after low battery indicator appears. Take off the battery cover.
  • Page 9: Error Displays And Troubleshooting

    ERROR DISPLAYS AND TROUBLESHOOTING Conductivity DISPLAY Possible cause(s) LCD Display Display Mode [Action(s)] Temperature >99.9° C range. [Bring solution to a "OVER" "OVER" Measure lower temperature.] electrode [Replace & ATC assembly Temperature <0.0°C range. [Bring solution to a "udr" Measure "OVER"...
  • Page 10: Specifications

    SPECIFICATIONS Conductivity Range Resolution Accuracy 5 uS/cm (40~2000 uS/cm) 0 to 20.00 mS/cm ±1% F.S. 0.05 mS/cm (2.00 ~ 15.00 mS/cm) 0.10 mS/cm (15.00 ~ 20.00 mS/cm) Range Resolution Accuracy 5 mg/L (20 ~ 1000 mg/L) 0.00 to 10.00 g/L ±1% F.S.
  • Page 11: Warranty

    If you purchased the item from our Jenco distributors and it is under warranty, please contact them to notify us of the situation. Jenco Service Department alone will determine if the product problem is due to deviations or customer misuse.
  • Page 12 6F., NO. 81, Sec.2, Chang-an E. Rd., Jhongshan District, Taipei City 104, Taiwan TEL: 886-2-2508-2928 FAX: 886-2-2508-2938 E-Mail: sales@JENCO.com.tw Website: www.JENCO.com.tw Shanghai Jenco Instruments, Ltd. 18 Wang Dong Zhong Road Sijing Town, Songjiang Shanghai, China TEL: 86-021-5761-9599 FAX: 86-021-5761-9598 E-Mail: jencos@jenco.com.cn...