CALIBRATION
CALIBRATION
TRIM CALIBRATION
[SKIP]
CALIBRATION
TRIM FULL DOWN
THEN PRESS PLUS BUTTON
[DFLT]
[SKIP]
CALIBRATION
TRIM FULL UP
THEN PRESS PLUS BUTTON
[DFLT]
[SKIP]
CALIBRATION
TRIM TO TRAILER POINT
THEN PRESS PLUS BUTTON
[DFLT]
[SKIP]
CALIBRATION
ACT. TRIM MAJOR PROFILE
( SKIP )
CALIBRATION
ACT. TRIM MAJOR PROFILE
1
( SAVE )
CALIBRATION
SPEED OPTIONS
[SKIP]
CALIBRATION
PITOT SENSOR
100 PSI TYPE
[ NO ]
[SAVE]
CALIBRATION
PITOT SENSOR
MULTIPLIER = 1.00
[DOWN]
[SAVE]
eng
SC 1000 TACHOMETER
Select "EDIT" to calibrate the gauge to the
standard 0–10° unit trim and 11–25° trailer
position scale. Select "SKIP" to advance to the
[EDIT]
next selection.
52661
Trim the system to the full down position, then
press the "+" button to save the setting.
[SAVE]
52662
Trim the system to the full up position, then
press the "+" button to save the setting.
[SAVE]
52663
Trim the system to the trailer point, then press
the "+" button to save the setting.
[SAVE]
52664
Select "EDIT" to select an active trim major
profile. Select "SKIP" to advance to the next
( EDIT )
selection.
67161
Select an active trim major profile. Select
"SAVE" to save the selection.
( UP )
67162
This section configures the following speed
sensors. Select "EDIT" to calibrate the
sensors. Select "SKIP" to proceed to the depth
[EDIT]
sensor screen.
52665
Select pitot transducer type. Choose between
100 or 200 psi. (100 psi is the most common.)
[YES ]
52671
Adjust the pitot pressure sensor to correct
display readings that are too high/low. Press
"–" or "+" to calibrate the pitot sensor multiplier
[ UP ]
"DOWN" or "UP."
52672
23