Atlantic WOYG112LCT Installation And Commissioning Instructions

Atlantic WOYG112LCT Installation And Commissioning Instructions

Air/water heat pump with integrated gas burner, split, 2 services, outdoor/hydraulic unit
Table of Contents

Advertisement

alféa hybrid duo gas
Air/water heat pump
with integrated gas burner,
split, 2 services
Outdoor unit
WOYG112LCT
WOYG140LCT
WOYK112LCT
WOYK140LCT
WOYK160LCT
Hydraulic unit
024200
Document n° 1485-9 ~ 26/07/2013
FR
EN
IT
DE
ES
PT
Installation and
commissioning
instructions
for professionals
to be kept by the user
for future reference
atlantic-comfort.com
The specifications of this equipment may
be modified without prior notice
Non-contractual document.
EN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WOYG112LCT and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Atlantic WOYG112LCT

  • Page 1 Document n° 1485-9 ~ 26/07/2013 Air/water heat pump with integrated gas burner, split, 2 services Outdoor unit Hydraulic unit WOYG112LCT 024200 WOYG140LCT WOYK112LCT WOYK140LCT WOYK160LCT Installation and commissioning instructions for professionals to be kept by the user for future reference atlantic-comfort.com...
  • Page 2 Heat pump alféa hybrid duo gas The following are required for the installation of this appliance: " qualified personnel, certified as capable of handling refrigerating fluids (according to environmental legislation ). " a heating engineer. Certificate of conformity The use of a gas boiler requires a Certificate of Conformity signed by local authorities. Installation and commissioning instructions "1485 - EN"...
  • Page 3: Table Of Contents

    Heat pump alféa hybrid duo gas Contents Presentation of the equipment ......5 Packaging General characteristics Optional equipment Description Scope of application...
  • Page 4 Heat pump alféa hybrid duo gas Commissioning ....... . . 41 Checks before commissioning Setting the combustion parameters during a gas check...
  • Page 5: Presentation Of The Equipment

    Heat pump alféa hybrid duo gas 1 Presentation of the equipment Packaging • 1 box: Choice of connection pipe. • 1 box: Outdoor unit. Concentric • 1 box: Hydraulic module with gas generator ... horizontal turbo pipe (073 224). and outdoor temperature sensor..
  • Page 6: General Characteristics

    Heat pump alféa hybrid duo gas General characteristics 11 three 14 three 16 three Model denomination alféa hybrid duo gas Gas category 2Esi3P CH - CZ - ES - IT - LT - PT - SK 2H3P DK - EE - FI - IT - SE LU - DE NOx class Nominal heating performances (T°...
  • Page 7 Heat pump alféa hybrid duo gas 11 three 14 three 16 three Model denomination alféa hybrid duo gas Domestic hot water tank Capacity of domestic hot water tank litre Max DHW circuit usage pressure (PMS) Specific DHW flow rate at DT 30°K (D) l/mn Max temperature °C...
  • Page 8 Heat pump alféa hybrid duo gas " Outdoor unit, hybrid duo gas 11 single phase model, hybrid duo gas 14+ single phase model Flow opening 4 holes Orifice d’écoulement (Ø 20) 4 trous Ø 10 Bottom view Vu e de dessous 1290 3/8”...
  • Page 9 Heat pump alféa hybrid duo gas " Hydraulic module Chimney connection Ø 80/125 49,3 Gas Ø 20x27 M Heating return Ø 26x34 M Heating flow Ø 26x34 M 1828 1800 1729 DHW Ø 20x27 M Cold water Ø 20x27 M 1229 271,5 Side view...
  • Page 10 Heat pump alféa hybrid duo gas 1 mbar = 10 mmCE = 100 Pa Outdoor sensor QAC34 mbar Ω 43907 1 kΩ, 25 °C 10000 2490 1000 °C Heat pump return sensor figure 3 - Hydraulic pressures and flow rates available Heat pump flow sensor Ω...
  • Page 11: Description

    Heat pump alféa hybrid duo gas Description " hybrid duo gas 11 & 14+ single phase " hybrid duo gas 11, 14 & 16 3-phase WO*K1**LCT Legend 1 - High performance impeller and low noise level. 2 - Electrical motor with variable "inverter" operation. 3 - "Inverter"...
  • Page 12 Heat pump alféa hybrid duo gas Legend: 15 - Pressure flap 16 - Disconnectable no return valve 1 - Chimney adaptor. 8 - Drainage tap 17 - Inspection trap a - Heating body 2 - Control panel: 18 - Titanium anode (ACI). b - Hot water exchanger Regulator / User interface, 19 - Adjustable feet...
  • Page 13: Operating Principle

    Heat pump alféa hybrid duo gas Legend: 1 - Regulator / User interface. figure 8 - 2 - On / off switch. Control panel 3 - ACI light 4 - Pressure gauge. 5 - Safety light. Operating principle The ambient sensor (optional) provides a corrective action to the water logic The heat pump transmits the energy in the outdoor air to The hydraulic module is equipped gas generator which...
  • Page 14 Heat pump alféa hybrid duo gas • Regulation functions • Operating principle of the domestic hot water (DHW) - The initial temperature of the heating circuit is controlled by water logic. DHW production takes priority over heating. - In function of an initial heating temperature, the power Two domestic hot water (DHW) temperatures may of the outdoor unit is modulated via the "inverter"...
  • Page 15: Installation

    Heat pump alféa hybrid duo gas 2 Installation Installation and maintenance rules 2.2.3 Containment of refrigerant circuits The appliance must be installed and the maintained All refrigerant circuits fear contamination from dust and moisture. If such pollutants introduced into refrigeration by an approved professional in accordance with the prevailing regulations and code of practice, in particular: circuit, they can contribute to degrade the reliability of...
  • Page 16 Heat pump alféa hybrid duo gas Positioning Installing the outdoor unit The choice of the position is particularly important 2.4.1 Installation precautions as having to move it later is a delicate operation that " The outdoor unit must only be installed requires a qualified person.
  • Page 17 Heat pump alféa hybrid duo gas become dirty or have excessive water dripping onto it (under a leaky drainpipe for example). • When operating water may escape from the outdoor unit. Do not install the appliance on a terrace; install it at a location which is drained (bed of gravel or sand).
  • Page 18 Heat pump alféa hybrid duo gas Installing the hydraulic module 2.5.1 Room where to install • The room where the appliance operates must respect 300 mm the regulations in force. This equipment may not be installed in a bathroom or a shower room. The atmospheric conditions in the room must not be humid;...
  • Page 19 Heat pump alféa hybrid duo gas Chimney evacuation pipe, B23, B23P The evacuation pipe must comply with the regulations in force The evacuation pipe must be dimensioned (according to standard NF EN 13384-1). The pipe must only be connected to a single appliance. The pipe must be waterproof.
  • Page 20 Heat pump alféa hybrid duo gas Room-sealed connection pipe C13, C33, C53 B23 type chimney connection The connection pipe must be removable. By design, the boiler's smoke temperature cannot exceed 120 °C, therefore, there is no need to add an evacuation pipe protection thermostat.
  • Page 21 Heat pump alféa hybrid duo gas C13 type pipe connection 90° 90° 90° 90° Mini 1899 mm 16 et 24 kW 1577 mm 28 et 34 kW 1698 mm ¤ 90° elbow = 1 m of straight pipe. ¤ 45° elbow = 0.5 m of straight pipe. Existing evacuation pipe.
  • Page 22 Heat pump alféa hybrid duo gas 2.8.2 Concentric vertical pipe (C33 type) C53 type pipe connection Regulations The roof terminal must be placed at least 0.40 m away from any opening windows and 0.60 m away from any ventilation air intake openings. Recommendations Respect the max authorised lengths (figure...
  • Page 23 Heat pump alféa hybrid duo gas Dormer Leaf Air inlet Dormer 0,6 m 0,4 m 0,4 m 0,4 m 0,6 m 0,4 m L < 1 m 0,4 m 0,4 m 0,4 m 0,4 m 0,4 m L > 1 m Pinion with leaf Blind pinion Roof rib...
  • Page 24 Heat pump alféa hybrid duo gas Refrigerant connections " This appliance uses the refrigerating fluid • Thermally insulate the gas and liquid pipe to avoid R410A. all condensation. Use insulating sleeves that resist temperatures of over 90°C. In addition, if the level of Respect the legislation for handling refrigerating fluids.
  • Page 25 Heat pump alféa hybrid duo gas 2.9.3 Flaring 2.9.5 Connecting the flare connections - Cut the tube with a tube cutter to the required length " Connections must be made the day of the filling without deforming it. the installation with gas (see para. 2.10, page 27).
  • Page 26 Heat pump alféa hybrid duo gas Heat pump model alféa hybrid gas single phase / three phase liquid Raccords unité extérieure 5/8" 3/8" Diameter (D1) 5/8" (D2) 3/8" Minimum length (L) Liaisons frigorifiques Maximum length (L) 15 * / 20 ** Difference in height (D) 15 * / 20 ** Hydraulic module connectors...
  • Page 27: Filling The Installation With Gas

    Heat pump alféa hybrid duo gas 2.10 Filling the installation with gas ANNEX 2 " This operation is reserved for installers familiar with the legislation for handling refrigerants. Method 3 empty " Creating a vacuum with a vacuum pump is essential (see ANNEX 1).
  • Page 28: Sealing Test

    Heat pump alféa hybrid duo gas • First seal test Refrigeration connecxion (Gas) Refrigeration connexion - Remove the protective plugs (B) from the charging hole (Schrader) in the "Gas" valve (large diameter). Plug (A) - Connect the high pressure hose to the Manifold 3-way valve - Connect the bottle of nitrogen to the Manifold (Use only dry nitrogen type U)
  • Page 29: Additional Charge

    Heat pump alféa hybrid duo gas 2.10.3 Additional charge 2.10.4 Collect the refrigerant fluid in the outdoor unit Carry out the following procedures to collect the 50 g of R410A per extra metre refrigerating fluid. Link length 15 m 20 m max. - 1- Place the Start/Stop switch in the 0 position (item 2, figure 8, page...
  • Page 30: Connecting The Heating Circuit And 15 The Domestic Circuit

    Heat pump alféa hybrid duo gas 2.11 Connecting the heating circuit and " In certain installations, the presence of different metals may cause corrosion problems; in which the domestic circuit case the formation of metal particles and sludge may be observed in the hydraulic circuit. 2.11.1 General "...
  • Page 31: Filling And Draining The Installation

    Heat pump alféa hybrid duo gas 2.11.3 Filling and draining the installation 2.11.6 Connection to the domestic circuit - Place a safety group with a valve calibrated to 7 bar on - Check the attachment of the pipes, that the connectors the cold water inlet, and connect an evacuation pipe are tight and that the hydraulic module is stable.
  • Page 32: Gas Change

    Heat pump alféa hybrid duo gas 2.13 Gas change " WARNING The gas generator is preset in the factory to Gas valve outlet G31 propane gas, domestic supply pressure: connector 37 mbar. • For use with G25 natural gas, domestic supply pressure: 25 mbar (Groninguen gas type), it is compulsory to remove the diaphragm on the gas valve outlet.
  • Page 33: Electrical Connections

    Heat pump alféa hybrid duo gas 2.15 Electrical connections Flexible wire (B) Before carrying out any work, ensure that the general electrical power supply is switched off. H07RNF (or higher quality) flexible wire can be used with a few precautions: 2.15.1 Characteristics of the electrical power supply - Strip the end of the wire over a length of around The electrical installation must comply with the...
  • Page 34: Overall View Of The Electrical Connections

    Heat pump alféa hybrid duo gas 2.15.3 Overall view of the electrical connections The electrical diagram of the hydraulic module is detailed in figure 59, page 64 Wireless room control unit T78 (option) Outdoor sensor: cable 2x0.5 mm² Wireless room thermostat T58 (option) Room control unit T75 (option): cable 3x0.5 mm²...
  • Page 35: Electrical Connections On Outdoor Unit Side

    Heat pump alféa hybrid duo gas 2.15.5 Electrical connections on outdoor unit side (single phase model) Access to the connector terminals - Make the connections according to the diagram - Remove the front panel. Remove the screws and the (figure 36).
  • Page 36: Electrical Connections On Outdoor Unit Side (Three Phase Model)

    Heat pump alféa hybrid duo gas 2.15.6 Electrical connections on outdoor unit side (three phase model) Access to the connector terminals - Remove the front panel. Remove the screws and the cover of the front panel. - Make the connections according to the diagram (figure 39).
  • Page 37 Heat pump alféa hybrid duo gas 2.15.7 Electrical connections on the hydraulic module side Access to the connector terminals Do not fit the sensor wires and the power supply wires in parallel in order to avoid interferences due to the - Remove the front panel.
  • Page 38 Heat pump alféa hybrid duo gas • Inter-connection between the outdoor unit and the hydraulic module: An incorrect connection can cause the destruction of Respect the correspondence between the terminal blocks references of the hydraulic module and those of the one of the units.
  • Page 39: Outdoor Sensor

    Heat pump alféa hybrid duo gas 2.17 Room thermostat • Second heating circuit and/or Room control unit - Refer to the instructions supplied with the 2 circuit hydraulic kit. The ambient thermostat (the central ambient unit) is • Load shedding or EJP (Delete peak rate day) optional The purpose of load shedding is to reduce the electrical Consult the assembly instructions on the packaging.
  • Page 40 Heat pump alféa hybrid duo gas Outdoor sensor Load shedding or EJP function Wireless room Wireless room (Peak Day Erasure) control unit thermostat T78** T58** Tariffs, day/night, peak/ off peak (not concerned) External fault * If the command does not supply a potential free contact, the contact must be relayed to obtain equivalent wiring.
  • Page 41: Commissioning

    Heat pump alféa hybrid duo gas 3 Commissioning Checks before commissioning Commissioning the heat pump - Engage the main isolator switch of the installation. 3.1.1 Hydraulic circuit: When first put into service (or in winter), to preheat - Make sure that the installation has been rinsed. the compressor, engage the main isolator switch - Check the circulator speed (figure...
  • Page 42: Heating Installation With

    Heat pump alféa hybrid duo gas Starting the gas generator to check the combustion To carry out the combustion checks (during a gas change or during maintenance), the gas generator can be started independently of the heat pump (figure 48) "...
  • Page 43: Hydraulic Circuit: 41 During A Gas Check

    Heat pump alféa hybrid duo gas Setting the combustion parameters during a gas check To carry out the combustion checks (during a gas change or during maintenance), the gas generator can be started independently of the heat pump (figure 48) "...
  • Page 44: Configuring Room Thermostat (T55 Or T58)

    Heat pump alféa hybrid duo gas Configuring room thermostat (T55 or T58) 2: Save with confirmation; a correction of the value with To configure the ambient sensor and associate it to the the knob is only adopted after pressing the operation adequate heating zone: button - Hold down the presence button for over 3s.
  • Page 45 ...
  • Page 46: Regulation

    Heat pump alféa hybrid duo gas 4 Regulation User interface, Room control unit (option) and Room thermostat (option) User interface Auto Auto °C Room control unit T75 / T78 Room thermostat T55 / T58 figure 51 - Installation and commissioning instructions "1485 - EN" - 46 -...
  • Page 47 Heat pump alféa hybrid duo gas Item Functions - Definitions of the functions Selecting the DHW operation - On: Production of DHW in function of the timer programme. - Off: Production of the DHW stopped with antifreeze function of the domestic water active.
  • Page 48 Heat pump alféa hybrid duo gas Description of the display Symbols Definitions - Compressor operation. - Burner operation authorisation. - Fault message (lists page 65, page 66) Xxxxxxxxxxxxxxxxxxxxxxxxxxx - Maintenance, special operation Xxxxxxxxxxxxxxxxxxxxxxxxxxx Xxxxxxxxxxxxxxxxxxxxxxxxxxx - Information level activated INFO (list page 70) PROG - Programming activated.
  • Page 49 Heat pump alféa hybrid duo gas Parameter 3700 (Release under ext. T°). Heat pump + gas generator operation 4 3,75 3,5 3,25 2,75 2,25 Traditional 1,75 radiator 1,25 Low temperature radiator 0,75 Underfloor heating (only with 2 circuit kit 0,25 option) Outdoor temperature °C figure 53 - Slope of the heating curve (line 720)
  • Page 50: Thermostat (Option) 46 General

    Heat pump alféa hybrid duo gas Regulation parameters 4.4.2 Setting the parameters - Selecting the desired level. 4.4.1 General - Scroll the list of menus. Only the parameters accessible at the levels: - Selecting the desired menu. U - end user. - Scroll the function lines.
  • Page 51 Heat pump alféa hybrid duo gas Line Function Setting Setting range or display Basic setting increment Temperature unit °C, °F °C Pressure unit bar, psi Version of display unit software * Heating time programme, circuit 1 Only appears with the 2 circuit kit option (if the installation has 2 heating circuits or 1 underfloor heating circuit). Preselection (day / week) Mon-Sun, Mon-Fri, Sat-Sun, Mon-Sun...
  • Page 52 Heat pump alféa hybrid duo gas Line Function Setting Setting range or display Basic setting increment * Holidays, Circuit 1 (for the holidays programme to be active the heating mode must be set to AUTO) Only appears with the 2 circuit kit option (if the installation has 2 heating circuits or 1 underfloor heating circuit). Period 1 Preselection Period 1 to 8...
  • Page 53 Heat pump alféa hybrid duo gas Line Function Setting Setting range or display Basic setting increment Start of increase in reduced functioning mode -30... 10 °C 1 °C End of increase in reduced functioning mode -30... 10 °C 1 °C -5 °C Mixer valve boost 0...
  • Page 54 Heat pump alféa hybrid duo gas Line Function Setting Setting range or display Basic setting increment Heating adjustment, Circuit 2 Basic programme for a simple, 1 radiator circuit installation 1010 Comfort ambient temperature setpoint from reduced setpoint… 0.5 °C 20 °C to comfort setpoint max 1012 Reduced ambient temperature setpoint...
  • Page 55 Heat pump alféa hybrid duo gas Line Function Setting Setting range or display Basic setting increment DHW setting (domestic hot water) 1610 Comfort setting Reduced value (line 1612)… 55 °C 65 °C 1612 Reduced setting 8 °C... 40 °C Comfort value (line 1610) 1620 Release of DHW load 24h / day...
  • Page 56 Heat pump alféa hybrid duo gas Line Function Setting Setting range or display Basic setting increment Additional generator (Boiler connection) 3692 With DHW charging Locked, Substitute, Substitute Complement, Instantly - DHW Instantly : When DHW request, the HP and the boiler are put into operation. The HP will stop when the primary return temperature is over 55 °C.
  • Page 57 Heat pump alféa hybrid duo gas Line Function Setting Setting range or display Basic setting increment 6420 H33 input function (=H4) Switching of heating circuit + DHW operation 6421 Contact type H33 Normally-closed contact (NC) Normally-opened contact (NO) LPB system 6600 Not used Error...
  • Page 58 Heat pump alféa hybrid duo gas Line Function Setting Setting range or display Basic setting increment 7719 PWM signal UX2 0... 100% 7722 Cooling operation D2 Off, On 7723 Heat pump D3 Off, On 7724 Outputs test U4 ("Inverter" command) 0...
  • Page 59 Heat pump alféa hybrid duo gas Line Function Setting Setting range or display Basic setting increment 8412 Heat pump flow temperature 0... 140 °C Setpoint (flow) HP 8413 Compressor modulation 0... 100% 8414 Modulation electric flow 0... 100% 8425 Condenser temperature differenc -50...
  • Page 60 Heat pump alféa hybrid duo gas Line Function Setting Setting range or display Basic setting increment 8760 Circulation pump, circuit 2 Off, On concerned 8770 Room temperature 2 0... 50 °C 20°C Ambient temperature setpoint 2 8773 Flow temperature 2 0...
  • Page 61 Heat pump alféa hybrid duo gas  Installation and commissioning instructions "1485 - EN" - 61 -...
  • Page 62: Electrical Wiring Diagrams

    Printed Circuit Board (Filter) Terminal Posistor Color Codes Earth Earth BK Black Terminal BN Brown WOYG112LBT / WOYG112LCT BU Blue WOYG140LBT / WOYG140LCT GN Green Interconnection Power source GY Grey between the outdoor unit 230 V OG Orange and the hydraulic unit.
  • Page 63 Heat pump alféa hybrid duo gas Re-injection pressure regulator coil Re-injection coil Temp. sensor. Pressure Inverter board regulator. Temp. sensor. Evaporator atmosphere Temp. sensor. Radiator P.F.C. Temp. sensor. Back-flow Temp. sensor. Evaporator output Compressor Temp. sensor. Temp. sensor. Condenser Outdoor Radiator board Inverter...
  • Page 64 Heat pump alféa hybrid duo gas Return Pressure Capteur Reset Retour Smoke Start sensor de pression Fumées Départ Ventilateur Carte Gas regulation régulation board Condensation Sonde sensor condensation Gas valve CN18 Vanne X18a CN16 Boitier CN30 Ignition unit allumage Transformateur Ignition allumage transformer...
  • Page 65: Fault Diagnostic

    Heat pump alféa hybrid duo gas 6 Fault diagnostic Depending on whether the fault is on the outdoor unit or the hydraulic module, the fault may be advised by the digital display or the LED on the interface boards. " Before carrying out any work, ensure that the general electrical power supply is switched off. "...
  • Page 66 Heat pump alféa hybrid duo gas Hydraulic module: Boiler regulator faults (LMS) visible on the digital display. Error codes Type of anomaly Probable causes Action Error on the boiler Shutdown of the Boiler sensor in - Check the sensor cabling sensor appliance short-circuit...
  • Page 67 Heat pump alféa hybrid duo gas Hydraulic module: Flashing LED visible on the 3 in 1 interface board. Error text Error description LED 2 (green) LED 1 (red) Error on communication between the hydraulic module and the outdoor 1 Flash 1 Flash unit 4 Flashes...
  • Page 68 Heat pump alféa hybrid duo gas Faults displayed on the single phase outdoor unit To access the electronic board, you must remove the front (right-hand) facing from the outdoor unit. Faults are coded by diode flashes. When an error occurs: - The diode "ERROR"...
  • Page 69: Faults Displayed On The 3-Phase Outdoor Unit

    Heat pump alféa hybrid duo gas Faults displayed on the 3-phase outdoor unit Diodes and switches To access the electronic board, you must remove the front (right-hand) facing from the outdoor unit. Faults are coded by diode flashes. When an error occurs: - The diode "ERROR"...
  • Page 70: On The Single Phase Outdoor Unit 68 Display Information

    Heat pump alféa hybrid duo gas Display information The Info button calls up various information. - Miscellaneous information (see below). Depending on the appliance type, the configuration and Designation Line the state of operation, certain information lines may not Floor drying current setpoint. be available.
  • Page 71: Servicing Of The Installation

    Heat pump alféa hybrid duo gas 7 Servicing of the installation Before carrying out any work, ensure that the general electrical power supply is switched off. The boiler must be serviced regularly to maintain high its output. Depending on the operating conditions, the servicing operation is to be carried out once or twice a year.
  • Page 72: Servicing Of The Gas Heat Exchanger 71 Checking The Outdoor Unit

    Heat pump alféa hybrid duo gas Servicing the evacuation pipe The suction pipe (or the chimney) must be checked and cleaned regularly by a specialist (once a year). - Check that the suction pipe is not obstructed. - Check that the condensate evacuation is not blocked. Remove the siphon and rinse it in clean water.
  • Page 73: Maintenance

    Heat pump alféa hybrid duo gas 8 Maintenance Flap closed (Normal operating Draining the hydraulic module position) - Remove the front panel of the heat pump. - Set the directional valve to intermediate position. - Deactivate the non-return valve (item 4, figure 66).
  • Page 74: Start-Up Procedure

    Heat pump alféa hybrid duo gas 10 Start-up procedure Before switching on the hydraulic module: • Check the electrical cabling • Check that the refrigeration circuit is filled with gas. • Check the hydraulic circuit's pressure (1 to 2 bars), check that the heat pump is drained, along with the rest of the installation.
  • Page 75 Heat pump alféa hybrid duo gas 10.1.2 Start-up • Starting (see § "3.2 Commissioning the heat pump", page 41). Non conforming Push in the installation's general circuit breaker (outdoor unit power supply) 2 hours before the tests => Compressor preheating. Push in the on/off switch =>...
  • Page 76: Commissioning Assistance "Check List" 74 Configuration File

    Heat pump alféa hybrid duo gas 10.2 Configuration file Parameter Designation Setting Menus Parameter Designation Setting Menus Boiler reading Prior settings 3700 On author. ext. T° addit. gener. language inter. Use Miscellaneous hour / minuts time and date 6420 H33 input function configuration day / month time and date...
  • Page 77: Before Starting 74 Technical Commissioning Instructions

    Heat pump alféa hybrid duo gas 10.3 Technical commissioning instructions Site Installer Serial No Serial No Outdoor unit Hydraulic module Model Model Type of refrigerating fluid Refrigerating fluid load Checks Voltages and intensities in operation on the outdoor unit Location distances respected L/N or L1/N Condensate evacuation OK L2/N...
  • Page 78 ...
  • Page 79 ...
  • Page 80 This appliance must be treated at a specialized treatment facility for re-use, recycling and other forms of recovery and shall not be disposed of in the municipal waste stream. Please contact the installer or local authority for more information. * subject to the national law of each member state Date of commissioning: atlantic-comfort.com www.atlantic.fr Société Industrielle de Chauffage SATC - BP 64 - 59660 MERVILLE - FRANCE...