Displaying the temperature information of the
device
Use the display environment command to display the temperature information of the device.
<Sysname> display environment
System Temperature information (degree centigrade):
--------------------------------------------------------------------------------
---------
Sensor
pperLimit
inflow 1
outflow 2
Table 12 Output description
Field
Sensor
Temperature
LowerLimit
Warning-UpperLimit
Alarm-UpperLimit
Shutdown-U

Displaying the operational statistics of the device

When you perform routine maintenance or the system fails, you might need to view the operational
information of each functional module for locating failures. Typically you need to run display
commands one by one. To collect more information one time, you can execute the display
diagnostic-information command in any view to display or save the operational statistics of
multiple functional modules of the device.
Save the operational statistics of each functional module of the device:
<Sysname> display diagnostic-information
Save or display diagnostic information (Y=save, N=display)? [Y/N]:y
Please input the file name(*.gz)[cfa0:/diag.gz]:
Diagnostic information is outputting to cfa0:/diag.gz.
Please wait...
Save successfully.
To view the diag.gz file:
a. Execute the gunzip diag.gz command in use view to decompress the file.
b. Execute the more default.diag command.
c. Press the Page Up and Page Down keys.
Display the operational statistics for each functional module of the device:
Temperature LowerLimit Warning-UpperLimit
27
0
46
0
Description
Temperature sensor:
Current temperature.
Low temperature alarm threshold.
Warning-level high temperature alarm threshold.
Alarm-level high temperature alarm threshold.
Shutdown-level high temperature alarm threshold. The device automatically
powers off when the temperature exceeds this threshold.
60
80
inflow—Air inlet vent temperature sensor.
outflow—Air outlet vent temperature sensor.
36
Alarm-UpperLimit Shutdown-U
70
92
NA
NA