Operation & Operation & Operation & Operation & Operation & Maintenance Maintenance Maintenance Maintenance Maintenance E38-PV f i r e - p a r t s . c o m Power-Vented Power-Vented Power-Vented Power-Vented Power-Vented Gas Fireplace Gas Fireplace Gas Fireplace...
E38-PV Gas Fireplace Introduction Table Of Contents About the E38-PV Power Vented Fireplaces: The E38-PV is rated for Natural Gas at 22,000 BTU/H (6.45 Kilo- Introduction ................2 watts) Input or Propane at 22,000 BTU/H (6.45 Kilowatts) Input. Installation Montigo's Power Vent system is ideal for extremely long or difficult Installing the Fireplace Shell .........
1". (0" clearance Figure 1. Fireplace dimensions. may be maintained around the vent pipes.) Header Clearances Shelf 1" Min. The E38-PV clearances to combustible materials are: Top* 1" 14 1/2 6" Min. Back 0" Side 1 ½"...
Installing The Remote Switch The gas line must be installed before finishing the E38-PV Fireplace. The E38-PV's gas valve, located behind the lower brass trim, may be Natural Gas requires a minimum inlet gas supply pressure of 5.5" connected to a wall switch or a hand-held remote. The valve operates W.C.
E38-PV Gas Fireplace Installation Vent Terminations Selecting A Termination Location Installing Power Vent 'Reverse' Terminations Before installing the termination or venting, check to ensure the When terminating a vent run below a soffit or an overhang, use the planned termination location is acceptable. For a detailed illustration Drop Termination to increase the clearance between the termination of allowed termination locations, see Appendix B.
The fireplace may ventout the right or left hand side. To convert: Installation Requirements 1. Lift off upper housing cover. E38-PV fireplaces are certified for use with Montigo Power Vent components and Standard Series (4" / 7") venting components 2. Disconnect flexible vent from the venter motor.
Installation Of Standard Series Direct Vent temp silicone except for the termination. Apply silicone to all Components joints and allow a 24 hour curing time before operating the The following venting components are available for the E38-PV: appliance. A - Termination MTO-3 (3" length) 2.
(See figure 13b). Ensure that a good seal is maintained when installing the door. Venting Plate Glass door & frame Figure 13b. Removing or installing the glass door. Figure 12. E38-PV insert. Page 8 Page 8 Part No. XM0500 Page 8 Page 8...
Installing the Logs: All 38 Series fireplaces may be equipped with optional fan or blower The E38-PV is supplied with five (5) fibre logs. Logs 'A' and 'B' are kits for circulating heat into the living space. factory installed on the mounting slots. They should be positioned as shown in figure 15a.
E38-PV Gas Fireplace Installation Finishing Around the Fireplace Combustible mantels and mouldings may be safely installed over the Painting: top and on the front of the fireplace provided that they do not project Special care is recommended by the Master Painters and Decorators beyond shaded area shown in Figure 16a.
E38-PV Gas Fireplace Operation with Honeywell Intermittent Pilot For Your Safety - READ BEFORE LIGHTING: WARNING: WARNING: WARNING: WARNING: WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
E38-PV Gas Fireplace Maintenance Gas Control Valve CAUTIONS CAUTIONS CAUTIONS CAUTIONS CAUTIONS Fireplace gas control must be in the “OFF” position and pilot and main burners extinguished when cleaning appliance with Honeywell (Q3450) Pilot Assembly a vacuum. Doors and logs can get very hot. Handle only when cool.
Page 13
E38-PV Gas Fireplace Maintenance Troubleshooting Removing the Power Vent Motor HONEYWELL SV 9500 /SV9600 WARNING: WARNING: WARNING: WARNING: WARNING: Troubleshooting Sequence Make sure power is off at household breaker or fuse NOTE: before starting. Before Troubleshooting, Familiarize Yourself With The Startup And Checkout Procedure.
The duration of any implied warranty with respect to this Montigo Gas Appliance is limited to the duration of the foregoing warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above may not apply to you.