Installation Operation & Maintenance EP28-4 4" B-Vented Gas Fireplaces EP28-4-2LB EP28-4-4LB Check local codes and read all Warning: For Your Safety: instructions prior to installation. Improper installation, adjustment, altera- Do not store or use gaso- tion, service or maintenance can cause line or other flammable ...
EC Plus-4 Series B-Vent ® Installation Finishing Around the Fireplace Combustible.mantels.and.mouldings.may.be.safely.installed.over.the. Mantels & Surrounds top.and.on.the.front.of.the.fireplace.provided.that.they.do.not.project. NOTE:.Mantel.clearances.shown.are.for.fire.hazard.prevention. beyond.shaded.area.shown.in.Figure 5a..Side.wall.clearances.are.0".. Combustible.surrounds.may.be.installed.with.0".clearance.to.the.side. New.technology,.to.meet.consumer.and.government.demands.for.the. wise.use.of.energy,.has.prompted.us.to.manufacture.many.models.of. of.the.fireplace.as.shown.in.Figure 5b. fireplaces.which.are.hot,.fuel.and.energy.efficient. Fireplace Facing Please.be.aware;.temperatures.over.the.mantel.will.rise.above.nor- mal.room.temperature.and.walls.above.fireplace.may.be.hot.to.touch. When.selecting.the.finish.material.for.your.fireplace,.it.is.important. to.remember.the.following:.TRIMS MUST NOT BE OBSTRUCTED We.recommend.careful.consideration.be.given.to.the.effects.of. IN ANY WAY - to do so restricts the air supply for the control elevated.mantel.temperatures.which.may.be.in.excess.of.product.
EC Plus-4 Series B-Vent ® Installation Wiring Optional Blower Kit Gas Control and Pilot Wiring EP-28-4-I EP-28 Series.decorative.fireplaces.may.be.equipped.with.an.optional. blower.kit (Part #FAN-28) for.circulating.heat.into.the.living.space. Honeywell (Q3450) Pilot Assembly Refer to Fan-28 Installation Instructions for more information. Installations in Canada.which.employ.the.fan.kit,.must.be.in.accord- Pilot Electrical Harness Connector ance.with.CSA C22.1.Canadian.Electrical.Code.Part.1.and/or.Local.
EC Plus-4 Series B-Vent ® Operation - Model EP28-4 EP-28-4 with Continuous Pilot For Your Safety - READ BEFORE LIGHTING: WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. This appliance has a pilot which must be lighted by Department. hand. When lighting the pilot, follow these instructions C. Use only your hand to push in or turn the gas control exactly. knob. Never use tools. If the knob will not push in or B.
EC Plus-4 Series B-Vent ® Operation - Model EP28-4-I EP-28-I with Honeywell Intermittent Pilot For Your Safety - READ BEFORE LIGHTING: WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance is equipped with an ignition system If you cannot reach your gas supplier, call the Fire that lights the pilot burner automatically. Do not at- Department.
EC Plus-4 Series B-Vent ® Maintenance Gas Control Valve CAUTION •. Fireplace.gas.control.must.be.in.the.“OFF”.position.and.pilot. and.main.burners.extinguished.when.cleaning.appliance.with. a.vacuum.. •. Glass.and.logs.can.get.very.hot..Handle.only.when.cool. General . Have.the.fireplace.installation.inspected.yearly,.including.a.visual. check.of.the.vent.system,.the.burner.and.the.pilot.flame..For.your. convenience.a.1/8".manifold.pressure.tap.is.supplied.on.the.gas. valve.for.a.test.gauge.connection..See.Figure.10a.and.10b... . For.Natural Gas.this.appliance.requires.a.minimum.inlet.pressure. of.5.5".W.C..and.a.manifold.pressure.of.3.5".W.C. . For.Propane Gas this.appliance.requires.a.minimum.inlet.pres- Spill Switch sure.of..11".W.C..and.a.manifold.pressure.of.10".W.C. . Always.keep.the.fireplace.area.clear.and.free.of.combustible. Figure 10a. Honeywell gas valve used on the EP28-2LB or the materials,.as.well.as.gasoline.and.other.flammable.vapours.and.
Page 11
EC Plus-4 Series B-Vent ® Maintenance Pilot Burner Adjustment Troubleshooting EP28-4-I 1. Determine.which.pilot.is.installed.in.the.fireplace.based.on.figure. HONEYWELL SV 9500 /SV9600 2.. Locate.Pilot.Adjustment.Screw..(See figures 10a..or.10b) Troubleshooting Sequence 3.. Adjust.pilot.key.to.provide.properly.sized.flame..(See figure 10a or NOTE: Before Troubleshooting, Familiarize Yourself With 10b). The Startup And Checkout Procedure.
In.order.for.any.claim.under.this.Warranty.to.be.valid,.The.Companies.must.be.notified.of.the.claimed.defect.in.writing.or.by.telephone,.as.soon.as.reasonably. possible.after.the.defect.is.discovered..Claims.against.this.Warranty.in.writing.should.include.the.date.of.installation,.and.a.description.of.the.defect. Other Rights Canadian Heating Products Inc. and/or Montigo DelRay Corp. reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Page 1 Part No. XG0303C...
Page 13
EC Plus-4 Series B-Vent ® Notes Part No. XG0303C Page 1...
Page 14
XG0303C - 112006 Montigo Del Ray Corp. Canadian Heating Products Inc. Ferndale,.WA...98248 Langley,.BC...V4W.4A1...