Montigo EP28-4 Installation, Operation And Maintenance Manual
Montigo EP28-4 Installation, Operation And Maintenance Manual

Montigo EP28-4 Installation, Operation And Maintenance Manual

4" b-vented gas fireplaces

Advertisement

Warning:
Improper installation, adjustment, altera-
tion, service or maintenance can cause
injury or property damage. Refer to this
manual. For assistance or additional
information consult a qualified installer,
service agency or the gas supplier.

What To Do If You Smell Gas:

• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in
your building.
• Immediately call your gas supplier from a neighbor's phone.
Follow the gas supplier's instructions.

For Your Safety:

Do not store or use gaso-
line or other flammable
vapors and liquids in the
vicinity of this or any other
appliance.
Installation
Operation &
Maintenance
EP28-4
4" B-Vented
Gas Fireplaces
EP28-4-2LB
EP28-4-4LB
Check local codes and read all
instructions prior to installation.
Installer: Leave this manual
with the appliance.
Consumer: Leave this man-
ual for future reference.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EP28-4 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Montigo EP28-4

  • Page 1: For Your Safety

    Installation Operation & Maintenance EP28-4 4" B-Vented Gas Fireplaces EP28-4-2LB EP28-4-4LB Check local codes and read all Warning: For Your Safety: instructions prior to installation. Improper installation, adjustment, altera- Do not store or use gaso- tion, service or maintenance can cause line or other flammable ...
  • Page 2: Table Of Contents

    This.manual.covers.installation,.operation.and.maintenance..Light- Wiring................6 ing,.operation.and.care.of.this.fireplace.can.be.easily.performed.by. Adjusting.the.Optional.Doors.......... 7 the.homeowner..However,.all.installation.and.service.work..should.be. Installing.the.Logset............7 performed.by.a.qualified.or.licensed.contractor,.plumber,.gasfitter,.or. installer.who.is.qualified.or.licensed.by.the.state,.province,.region,.or. Operation.................8-9 governing.body.in.which.the.appliance.is.being.installed. Model.EP28-4..............8 The.warranty.will.be.voided.by,.and.the.manufacturer disclaims.any. Model.EP28-4-I............... 9 responsibility.for,.the.following.actions: Maintenance................ 10-11 . Modification.of.the.fireplace.and/or.components.including.com- bustion.air.assembly.or.glass.doors. Warranty................... 12. . Use.of.any.component.part.not.manufactured.or.approved.by.the. manufacturer.in.combination.with.an.EC-Plus.fireplace.system. . Installation.other.than.as.instructed.in.this.manual.
  • Page 3: Installation

    EC Plus-4 Series B-Vent ® Installation Installing The Fireplace Shell The.fireplace.may.be.installed.in.any.location.that.maintains.clear- Framing ances.to.air.conditioning.ducts,.electrical.wiring.and.plumbing..Safety,. For.protection.against.freezing.temperatures,.it.is.recommended.that. as.well.as.efficiency.of.operation,.must.be.considered.when.selecting. outer.walls.of.the.chase.be.insulated.with.a.vapour.barrier..This.will. the.fireplace.location..Try.to.select.a.location.that.does.not.interfere. reduce.the.possibility.of.a.cold-air.convection.current.on.the.fireplace. with.room.traffic,.has.adequate.ventilation,.and.offers.an.accessible. pathway.for.the.optional.B-Vent.&.Combustion.Air.Kit.installation. The.fireplace.dimensions.are.shown.below: 14 3/4 4".B-Vent 4' B-Vent Top View 37 1/2 9 1/2 15 1/2* 37 1/2 31 1/4 When.sheetrock.is.not.used.behind.the.fireplace,.framing. depth..may.be.reduced.to.14.3/4" Figure 2.
  • Page 4: Installing.the.gasline

    EC Plus-4 Series B-Vent ® Installation Installing The Gas Line Installing The Remote Switch The.gas.line.must.be.installed.before.finishing.the.fireplace..Natural The.EP-28-4 Series is.equipped.with.a.remote-operated.valve,. Gas.requires.a.minimum.inlet.gas.supply..pressure.of.5.5".W.C..&.a. located.behind.the.removable.brass.grille,.to.the.right.of.the.gas. manifold.pressure.of.3.5".W.C..Propane Gas.requires.a.minimum.in- control.valve.(refer.to.Figure.10a.and.10b.).The.valve.is.pre-wired.and. let.gas.supply.pressure.of.11".W.C..&.a.manifold.pressure.of.10".W.C.. completely.self.contained.to.generate.its.own.power. DO NOT.con- Provision.must.also.be.made.for.a.1/8".N.P.T..plugged.tapping.and.be. nect.any.external.power.to.it. accessible.for.test.gauge.connection.immediately.upstream.of.the.gas. Note:. The.switch.location.must.not.exceed.30'.from.the.fireplace. supply.controls.to.the.appliance...The.fireplace.gas.connection.and. the.main.operating.gas.valve.is.located.behind.the.removable.brass. B-Vent Installation trim.at.the.bottom.of.the.unit.and.need.only.be.attached.to.the.gas.line. . with.an.approved.fitting,.as.required.by.the.applicable installation The.EP-28-4 Series is.certified.for.use.with.standard.4"...
  • Page 5: Facing

    EC Plus-4 Series B-Vent ® Installation Finishing Around the Fireplace Combustible.mantels.and.mouldings.may.be.safely.installed.over.the. Mantels & Surrounds top.and.on.the.front.of.the.fireplace.provided.that.they.do.not.project. NOTE:.Mantel.clearances.shown.are.for.fire.hazard.prevention. beyond.shaded.area.shown.in.Figure 5a..Side.wall.clearances.are.0".. Combustible.surrounds.may.be.installed.with.0".clearance.to.the.side. New.technology,.to.meet.consumer.and.government.demands.for.the. wise.use.of.energy,.has.prompted.us.to.manufacture.many.models.of. of.the.fireplace.as.shown.in.Figure 5b. fireplaces.which.are.hot,.fuel.and.energy.efficient. Fireplace Facing Please.be.aware;.temperatures.over.the.mantel.will.rise.above.nor- mal.room.temperature.and.walls.above.fireplace.may.be.hot.to.touch. When.selecting.the.finish.material.for.your.fireplace,.it.is.important. to.remember.the.following:.TRIMS MUST NOT BE OBSTRUCTED We.recommend.careful.consideration.be.given.to.the.effects.of. IN ANY WAY - to do so restricts the air supply for the control elevated.mantel.temperatures.which.may.be.in.excess.of.product.
  • Page 6: Wiring

    EC Plus-4 Series B-Vent ® Installation Wiring Optional Blower Kit Gas Control and Pilot Wiring EP-28-4-I EP-28 Series.decorative.fireplaces.may.be.equipped.with.an.optional. blower.kit (Part #FAN-28) for.circulating.heat.into.the.living.space. Honeywell (Q3450) Pilot Assembly Refer to Fan-28 Installation Instructions for more information. Installations in Canada.which.employ.the.fan.kit,.must.be.in.accord- Pilot Electrical Harness Connector ance.with.CSA C22.1.Canadian.Electrical.Code.Part.1.and/or.Local.
  • Page 7: Adjusting.the.optional.doors

    EC Plus-4 Series B-Vent ® Installation Optional Doors Logset Installation EC-Plus.4-Series.Fireplaces.come.standard.with.a.firescreen,.and. EP28-4-2LB Logset may.be.fitted.with.one.of.the.following.optional.door.kits: This.burner.assembly.is.supplied.with.two.(2).cultured.oak.logs..To. . Twin-Pane-Style.Doors.. Part.#.EP-TWD28 install.simply.place.log.A's.rectangular.shaped.extension.into.the.log. Bi-Fold.Doors. . Part.#.EP-BD28 . mounting.slot.located.on.rear.wall.of.the.burner.assembly..Place.log. Stereo.Cabinet.Doors. . Part.#.EP-TWD28E . B.onto.front.log.slots.as.shown.below. Twin-Pane.and.Bi-Fold.Doors.are.available.in.Black,.Brass.or.Nickel. Finshes.to.match.your.fireplace's.trim..Stereo.Cabinet.Doors.are.an. all-glass.design. Log.'B' Log.'A' Installation Complete.installation.instructions.are.included.with.the.door.kit. Adjustment After.installation.of.the.fireplace,.the.doors.may.require.some.adjust- ment. The.spring.clips.that.are.installed.on.both.sides.of.the.top.door.rail.
  • Page 8: Operation

    EC Plus-4 Series B-Vent ® Operation - Model EP28-4 EP-28-4 with Continuous Pilot For Your Safety - READ BEFORE LIGHTING: WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. This appliance has a pilot which must be lighted by Department. hand. When lighting the pilot, follow these instructions C. Use only your hand to push in or turn the gas control exactly. knob. Never use tools. If the knob will not push in or B.
  • Page 9: Model.ep28-4-I

    EC Plus-4 Series B-Vent ® Operation - Model EP28-4-I EP-28-I with Honeywell Intermittent Pilot For Your Safety - READ BEFORE LIGHTING: WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance is equipped with an ignition system  If you cannot reach your gas supplier, call the Fire that lights the pilot burner automatically. Do not at- Department.
  • Page 10: Maintenance

    EC Plus-4 Series B-Vent ® Maintenance Gas Control Valve CAUTION •. Fireplace.gas.control.must.be.in.the.“OFF”.position.and.pilot. and.main.burners.extinguished.when.cleaning.appliance.with. a.vacuum.. •. Glass.and.logs.can.get.very.hot..Handle.only.when.cool. General . Have.the.fireplace.installation.inspected.yearly,.including.a.visual. check.of.the.vent.system,.the.burner.and.the.pilot.flame..For.your. convenience.a.1/8".manifold.pressure.tap.is.supplied.on.the.gas. valve.for.a.test.gauge.connection..See.Figure.10a.and.10b... . For.Natural Gas.this.appliance.requires.a.minimum.inlet.pressure. of.5.5".W.C..and.a.manifold.pressure.of.3.5".W.C. . For.Propane Gas this.appliance.requires.a.minimum.inlet.pres- Spill Switch sure.of..11".W.C..and.a.manifold.pressure.of.10".W.C. . Always.keep.the.fireplace.area.clear.and.free.of.combustible. Figure 10a. Honeywell gas valve used on the EP28-2LB or the materials,.as.well.as.gasoline.and.other.flammable.vapours.and.
  • Page 11 EC Plus-4 Series B-Vent ® Maintenance Pilot Burner Adjustment Troubleshooting EP28-4-I 1. Determine.which.pilot.is.installed.in.the.fireplace.based.on.figure. HONEYWELL SV 9500 /SV9600 2.. Locate.Pilot.Adjustment.Screw..(See figures 10a..or.10b) Troubleshooting Sequence 3.. Adjust.pilot.key.to.provide.properly.sized.flame..(See figure 10a or NOTE: Before Troubleshooting, Familiarize Yourself With 10b). The Startup And Checkout Procedure.
  • Page 12: Warranty

    In.order.for.any.claim.under.this.Warranty.to.be.valid,.The.Companies.must.be.notified.of.the.claimed.defect.in.writing.or.by.telephone,.as.soon.as.reasonably. possible.after.the.defect.is.discovered..Claims.against.this.Warranty.in.writing.should.include.the.date.of.installation,.and.a.description.of.the.defect. Other Rights Canadian Heating Products Inc. and/or Montigo DelRay Corp. reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Page 1 Part No. XG0303C...
  • Page 13 EC Plus-4 Series B-Vent ® Notes Part No. XG0303C Page 1...
  • Page 14 XG0303C - 112006 Montigo Del Ray Corp. Canadian Heating Products Inc. Ferndale,.WA...98248 Langley,.BC...V4W.4A1...

This manual is also suitable for:

Ep28-4-2lbEp28-4-4lb

Table of Contents