Operating instructions (original) Wastewater filter system AS 300 Type 328 Language: EN Version: 2 Phone: 02874/9156-0 deconta GmbH Fax: 02874/9156-11 Date of issue: Im Geer 20 E-Mail: info@deconta.com 22.05.2024 46419 Isselburg Web: www.deconta.com...
External transport ....................18 6.2.1 Transport space ..................18 6.2.2 Legislation ....................18 6.2.3 Qualification of staff ................18 6.2.4 Warning of residual risks ................. 18 Waste water filter system AS 300 2 from 30 Original operating instructions Version 2...
Page 3
14 Storage ........................... 28 15 Waste disposal....................... 29 15.1 Qualification of staff ....................29 15.2 Legislation ......................29 15.3 Waste ........................29 16 EC Declaration of Conformity ..................30 Waste water filter system AS 300 3 from 30 Original operating instructions Version 2...
Name and address deconta GmbH Im Geer 20 46419 Isselburg Telephone 02874/9156-0 02874/9156-11 e-mail info@deconta.com Internet www.deconta.com Change index date Version Amendment Responsible 12.03.2024 Complete revision Thomas Boland Waste water filter system AS 300 4 from 30 Original operating instructions Version 2...
If the machine is handed over to another person, the operator passes these operating instructions on to this person. Waste water filter system AS 300 5 from 30 Original operating instructions Version 2...
Description of the hazard and the cause of the hazard Consequence Description of the possible consequences of the hazard for humans, animals and the environment Escape Recommendations on how hazards can be avoided Waste water filter system AS 300 6 from 30 Original operating instructions Version 2...
The instruction sign is a safety sign that prescribes certain behaviour. The following table provides an overview of the instruction symbols used and their meaning. Symbol Meaning Symbol Meaning Wear safety shoes Use protective clothing Waste water filter system AS 300 7 from 30 Original operating instructions Version 2...
General description General description of the product The wastewater filter system was designed and built by the company deconta GmbH, Im Geer 20, 46419 Isselburg. Contaminated wastewater is cleaned via a 3-stage filter unit consisting of a pre-filter and 2 fine filters.
▪ As listed above ▪ Thoroughly cleaned (ready for use) ▪ Without residual fibre bonding ▪ Without filter ▪ Without damage Waste water filter system AS 300 9 from 30 Original operating instructions Version 2...
Product - waste products: Geka connection for filtered wastewater into the sewage system ▪ Product - material feed: Geka connection for contaminated water ▪ Product - base: castors / feet Waste water filter system AS 300 10 from 30 Original operating instructions Version 2...
The following accessories are optionally available for the wastewater filter system: Designation Article no. Illustration Wastewater hose 5m with 3/4" Geka BU1504 connection Wastewater hose with proximity BU1629 switch Waste water filter system AS 300 11 from 30 Original operating instructions Version 2...
10" 220 (disposable) ▪ Fine filter: 10" 50 (disposable) ▪ Fine filter: 10" 1 (disposable) ▪ max. medium temperature: 50°C at 4bar Subject to technical changes Waste water filter system AS 300 12 from 30 Original operating instructions Version 2...
For this reason, objects that leave the decontamination area via airlocks must be cleaned. The deconta wastewater filter system treats (filters) the contaminated wastewater. The user must comply with the operating parameters specified in the operating instructions.
Operating the machine in a technically unsatisfactory condition, not being aware of safety and hazards and not observing all instructions in the documentation Use in potentially explosive atmospheres Waste water filter system AS 300 14 from 30 Original operating instructions...
Qualified waste disposal Disposer Dispose of the machine company for legally compliant, proper and professional disposal of the machine Waste water filter system AS 300 15 from 30 Original operating instructions Version 2...
Instruction of persons with regard to protective devices and supplementary protective devices Instruction of persons with regard to residual risks This list is not exhaustive and does not claim to be complete. Waste water filter system AS 300 16 from 30 Original operating instructions Version 2...
Transport is the movement of the machine by manual or technical means. In winter, it is essential to pay attention to the risk of frost: Empty water pipes, tank, filter housing and pumps Vent connection Drain plug Waste water filter system AS 300 17 from 30 Original operating instructions Version 2...
Machine may fall due to unintentional change of position when loading and unloading onto/from a means of transportation. Waste water filter system AS 300 18 from 30 Original operating instructions Version 2...
The wastewater filter system is delivered ready for operation ex works and is intended for immediate commissioning. Do not operate the appliance if it is visibly damaged. Contact deconta GmbH immediately. Waste water filter system AS 300 19 from 30...
Connect the wastewater hose to the "IN" connection and connect to the place of use ▪ Connect the "OUT" connection to the sewer ▪ Establish 230V power supply (earthed plug) Waste water filter system AS 300 20 from 30 Original operating instructions Version 2...
The proximity sensor on the wastewater hose recognises whether there is water in the hose and then switches the wastewater filter system on or off. The sensitivity of the proximity sensor can be readjusted using the screwdriver supplied. Waste water filter system AS 300 21 from 30 Original operating instructions...
One person is required to use the machine. Tools required No tools are required to use the machine. Equipment required No equipment is required to use the machine. Waste water filter system AS 300 22 from 30 Original operating instructions Version 2...
Only change filters when the appliance is switched off. Only use approved filters. Pull out the mains plug before opening the housing Waste water filter system AS 300 23 from 30 Original operating instructions Version 2...
Only use approved filters ▪ Damaged filter cartridges must not be used Union nut „OUT" connection Pressure gauge Pre-filter 220µ Fine filter 1µ Fine filter 5µ Filter head spanner Waste water filter system AS 300 24 from 30 Original operating instructions Version 2...
Page 25
Repairs and maintenance work may only be carried out in compliance with all relevant safety measures. The filters must be disposed of in accordance with legal regulations. Waste water filter system AS 300 25 from 30 Original operating instructions Version 2...
If this is not possible, the alternative spare parts should correspond to the properties of the original spare parts in order to ensure safe, trouble-free and economical use of the machine. Waste water filter system AS 300 26 from 30...
The optional hoses may only be stored completely drained and cleaned! During storage, care must be taken to ensure that contamination with other substances is excluded. Wastewater hoses must be stored separately from fresh water hoses. Waste water filter system AS 300 28 from 30 Original operating instructions...
15.3 Waste The waste generated by the machine must be disposed of properly and professionally in accordance with the law. Waste water filter system AS 300 29 from 30 Original operating instructions Version 2...
The protection targets of the following other legal regulations were met: Low Voltage Directive 2014/35/EU Name and address of the person authorised to compile the technical documentation: Boland, Thomas - deconta GmbH, Im Geer 20 - 46419 Isselburg The following harmonised standards were applied: EN 60204-1:2018...