Time program
(cont.)
■
For central heating, up to 4 changes per day
between standard and reduced room temperature
can be programmed (4 time phases).
At the factory, time phase
■
is set for all days of the week. During that time, the
rooms are heated to the standard room temperature.
■
You can set switching times individually for the fol-
lowing days or parts of the week:
The same for every day: Monday to Sunday
–
For individual parts of the week: Monday to Friday
–
and Saturday to Sunday
–
For every day individually: Monday, Tuesday, etc.
■
In the "Extended menu", you can check the current
time program under "Information". See page 39.
Setting time phases
Heating time program
Monday-Sunday
Monday-Friday
Saturday-Sunday
Monday
Select with
Fig. 14
Press the following buttons:
1.
for the "Extended menu".
å
2.
/
for "Heating".
|
~
3.
to confirm.
d
4.
/
to select "Heating circuit 1" (HC1), "Heat-
Ù
Ú
ing circuit 2" (HC2), "Heating circuit 3"
(HC3) or "Heating circuit 4" (HC4, if
installed).
5.
/
for "Heating time program".
|
~
6.
to confirm.
d
7.
/
until the required part of the week or day
|
~
appears.
Deleting time phases
1. Set the time for the end point to the same time that
was set for the start point.
The display shows "- - : - -".
2. Press
to confirm.
d
from 06:00 to 22:00 h
!
HC1
Note
When setting the switching times, please bear in mind
that your heating system requires some time to heat
the rooms to the required temperature.
8.
to confirm.
d
9.
/
to select the time phase.
|
~
The relevant time phase is represented by
a number (
!
Heating
0
2
4
6
8 10 12 14 16 18 20 22 24
06:00 - 22:00
!
? - -:- - - - -:- -
Select with
Fig. 15
10.
to confirm.
d
11.
/
to set the start point.
|
~
12.
to confirm.
d
13.
/
to set the end point.
|
~
14.
to confirm.
d
15. To set the beginning and end of further time pha-
ses, proceed as described in steps 9 to 14.
To set further time phases, proceed as described in
steps 7 to 14.
Heating
Mo-Fr
HC1
0
2
4
6
8 10 12 14 16 18 20 22 24
- -:- - - - -:- -
Std
?
u
- -:- - - - -:- -
Std
§
u
Adopt with
OK
Fig. 16
Central heating
,
,
or
).
?
§
$
Mo-Su
HC1
Std
u
---
u
(
19