The bottom housing will need to be removed to access internal assemblies or if it needs to be replaced. The CN70A
bottom housing is secured with 8 screws while the CN70E bottom housing is secured with 10 screws.
Tools Required
Description
T10 Torx driver
Parts Required
Item Part Number
1
715-564S-004
2
715-565S-004
3
643-051-001
4
800-570-002
5
655-334-001
6
906-016-002
7
715-627S-005
8
715-627S-006
715-564S-006
NOTE 1: The GOBI bottom for Southwest Airlines (SWA) does not have a handstrap or stylus installed. Otherwise
the Southwest Airlines spare bottom housings are mechanically the same.
NOTE 2: The bottom Geopost configuration CN70AN3GCU3AN100 has a different handstrap custom for Geopost.
Otherwise the bottom housing is the same as for standard CN70A.
Continued on next page...
Description
CN70A Spare Bottom Housing
CN70E Spare Bottom Housing
Plug
SCREW 4-40X1/2 PH TORX W/NYL CRES ROHS
Spacer, ZIF (for CN70A)
Kapton tape (for CN70E) (use 1.7 inches)
Cover BtmassyStrght CDMA SWA Spare CN70
Cover,Btmassy Strght GOBI SWA Spare CN70 (see NOTE 1)
Housing,Bottom Potted Assy Geopost (see NOTE 2)
Model
DOCUMENT NO.
CN70A,CN70E
SWICN70-000
Part Number
1
3
4
5
2
PAGE
Page 8 of 45
Qty
1
1
2
8-10
1
1
1
1
1
6