Side Scan Pcb's - Honeywell CN70 Series Service Work Instructions

Hide thumbs Also See for CN70 Series:
Table of Contents

Advertisement

TITLE
CN70 Service Work Instructions

Side Scan PCB's

OPERATION:
The side scan PCB's are located on the scan bracket assembly one on each side. They can be removed and installed
without removing the scan bracket assembly.
Tools Required
Description
T10 Torx driver
Phillips screwdriver with #0 tip
Parts Required
Item Part Number
1
224-873S-0100
2
800-450-003
Removal
1. Remove the bottom housing assembly (refer to Bottom Housing operation).
2. Using a #0 Phillips screwdriver remove 2 screws that secure the side scan PCB to the scan bracket assembly.
Installation
1. Position the side scan PCB at its location on the scan bracket assembly.
2. Using a #0 Phillips screwdriver install 2 screws and secure the side scan PCB to the scan bracket assembly with
1.2+/-0.2 in-lbs of torque.
3. Re-install the bottom housing assembly.
Description
Side Button Board
Thd Form Screw,M1.7 x 3mm Flat Hd RoHS
Model
DOCUMENT NO.
CN70A,CN70E
SWICN70-000
Part Number
1
PAGE
Page 20 of 45
Qty
1
2
2