Replacing The Injectors; Regulating The Minimum Flow Level Of The Gas Taps - KitchenAid KHDD2 38510 Instructions For Use Manual

Table of Contents

Advertisement

Replacing the injectors

Note: Refer to the injector table earlier in the manual to
ensure the correct type of injector is to be fitted.
Traditional burners (T)
1. Remove the cap (A).
2. Remove the spreader (B).
3. Unscrew the injector (C) with a box spanner 7.
4. Replace the injector with the one for the new gas.
5. Put back burners and pan supports.
Note: Before installing the hob, please remember to stick
the gas calibration label, provided with the replacement
injectors over the gas information on the underside of the
hob.

Regulating the minimum flow level of the gas taps

Regulating the minimum flow level must be done with the
tap at the lowest position (small flame)
There is no need to regulate the primary air in the
burners. To ensure the minimum level is properly
regulated, remove the control knob and adjust the screws
found on the tap as follows:
1. tighten to reduce the height of the flame 1 (-)
2. slacken to increase the height of the flame (+);
3. With the burners on, rotate the buttons from the
maximum
to the minimum position
stability of the flame.
NOTE:
Service and maintenance only to be carried by an
authorized person.
To replace the parts such as burners, valve and electric
components, the hot plate must be removed from the
bench top by releasing the attachment hooks, loosening
the attachment screws of each burner, unscrewing the
hotplate attachment nuts.
Note: If the valves must be replaced, first disassemble the
chain if ignition switches.
It is recommended to replace the valve gasket each time
the valve is replaced thus ensuring a perfect seal between
the body and the gas train.
WARNING: DO NOT MODIFY THIS APPLIANCE