Sfp Modules; Table 3-6 Configuring Triggering Condition; Table 3-7 Parameters Of The Di Interface - Raisecom Gazelle S1512i-4GF-8GE-PWR User Manual

Table of Contents

Advertisement

Raisecom
Gazelle S1512i-PWR (A) User Manual
The DI interface supports 2 ways of DI and up to 8 mA input current. Each way of DI
supports the following two statuses:
After login, you can configure the triggering condition of an external alarm to high level or
low level in global configuration mode as required, as described in Table 3-6.

Table 3-6 Configuring triggering condition

1
2
Table 3-7 lists parameters of the DI interface.

Table 3-7 Parameters of the DI interface

Connector type
Input voltage range
High level
Low level
Maximum input current

3.2 SFP modules

All Raisecom modules comply with RoHS and all Raisecom optical modules support DDM.
PIN
Negative terminal
High level: the input voltage is 13–30 VDC.
Low level: the input voltage is -30 to 1 VDC.
Step
Command
Raisecom#config
Raisecom(config
)#alarm
outside-alarm
num
{ high |
low }
Parameter
Raisecom Proprietary and Confidential
Copyright © Raisecom Technology Co., Ltd.
Description
Enter global configuration mode.
Configure the triggering condition of an external alarm
to high level or low level.
Num: being 1 or 2, DI ID
High: configure the triggering condition to high level.
Low: configure the triggering condition to low level.
By default, each external alarm is triggered by
high level.
5.08 mm × 5-pin Phoenix connector
-30 to +30 VDC
+13 to +30 VDC
-30 to +1 VDC
8 mA
3 Interfaces and modules
Description
Description
18

Advertisement

Table of Contents
loading