Technical Specifications - Flex ADM 60 Operating Instructions Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 11
FLEX ADM 60
mode). Holding down the button starts
a continuous measurement
15 Measuring mode button
Switches the measuring modes in succes-
sion: Area measurement
measurement
double Pythgorean
ment
.
16 Reference plane button
Switches the reference planes in succes-
sion: Base of device
of device
, stop pin
17 Unit of measurement button
Switches the units of measurement
in succession: metric (m, mm),
Anglo-American (ft, in).
18 Min/Max button
Activates the maximum or minimum
measurement.
19 Plus/Minus button
For adding + or subtracting – measured
values.
20 Clear button
Deletes the last measured value or swit-
ches on linear measurement (depending
on selected measuring mode).
14
.
, volume
, single Pythagorean
linear measure-
, ¼" thread
, front
.

Technical specifications

Laser range finder ADM 60
Visible laser diode
,
Laser class
Measurement range *
Precision *
Smallest display size
Power supply
Operating duration
Individual measurements (number) ≤ 5000
Automatic switch-off
– Laser beam
– Measuring instrument
Temperature range
– for operation
– for storage
Weight (with batteries)
* The measurement range may be less under
unfavourable conditions (bright sunlight, reflec-
tive surfaces). It is recommended to use a laser
target plate (optional).
620–690 nm
2
0.1–60 m
± 2 mm
1 mm
4 x LR03/AAA
20 s
300 s
0 °C ... 40 °C
–20 °C ... 60 °C
0.195 kg

Advertisement