[Source:]Current:limit[:Level][:Cv]; Current:protection - ITech IT8600 Series Manual

Programmable ac/dc electronic load
Hide thumbs Also See for IT8600 Series:
Table of Contents

Advertisement

Parameter:
MINimum|MAXimum|DEFault or NRf
Reset value:
MINimum
Unit:
A
Query Syntax:
[SOURce:]CURRent[:LEVel][:IMMediate][:AMPLitude]? [MINimum|MAXimum]
Returned value:
NR3

[SOURce:]CURRent:LIMit[:LEVel][:CV]

This command is used to set the maximum current value in CV mode.
Command syntax
[SOURce:]CURRent:LIMit[:LEVel][:CV]
Parameter:
MINimum|MAXimum|DEFault or NRf
Unit
A
Reset value:
MAXimum
Query Syntax:
[SOURce:]CURRent:LIMit[:LEVel][:CV]? [MINimum|MAXimum]
Returned value
<NR3>

CURRent:PROTection

This command is used to set software overcurrent protection level ofelectronic
load.