3.3.8 Changing the Device Lost timeout

The Diagnostics Device waits for a certain time before it considers a slave to be lost. This works in a similar way
as the ProfiTrace Live List, where the background turns yellow when a slave stops communicating. This timeout
can be changed in steps of 1 second. Default value is 5, and maximum value is 255.

3.3.9 Changing the data format

The data format can be changed if needed. Default is Motorola, high-low-byte format.
You can change it to Intel, low-high-byte format.
ProfiHub B2FOR+ / B4FOR+ User Manual | August 2019 | © PROCENTEC
39/60