  • Page 1 ProfiHub B2FO2+ User Manual...
  • Page 2 However, the content in this manual is reviewed regularly and any necessary corrections included in subsequent editions. Suggestions for improvement are welcomed. ProfiHub B2FO2+ User Manual – v2.1.0 | 29 December 2016 | © PROCENTEC 1/38...
  • Page 3: Important Information

    Tel.: +31-(0)174-671800 Fax: +31-(0)174-671801 Email: info@procentec.com Document Updates You can obtain constantly updated information on PROCENTEC products on the Internet at www.procentec.com. You can also contact PROCENTEC Customer Support: • By phone at +31-(0)174-671800 • By fax at +31-(0)174-671801 • By email at support@procentec.com ProfiHub B2FO2+ User Manual –...
  • Page 4: Table Of Contents

    Channel Redundancy......................19 3. Technical Data ProfiHub B2FO2+ ......... 21 4. Sales offices and distributors ........24 5. Order codes ..............29 6. Glossary ................ 30 ProfiHub B2FO2+ User Manual – v2.1.0 | 29 December 2016 | © PROCENTEC 3/38...
  • Page 5 7. About PROCENTEC ............33 8. Revision history ............34 9. Notes ................35 ProfiHub B2FO2+ User Manual – v2.1.0 | 29 December 2016 | © PROCENTEC 4/38...
  • Page 6: Product Description

    ProfiHubs are equipped with LEDs on the outside, which indicate the status of each Channel (Data and Error). Fig. 1 - ProfiHub B2FO2+ ProfiHub B2FO2+ User Manual – v2.1.0 | 29 December 2016 | © PROCENTEC 5/38...
  • Page 7: Product Features

    Fig. 3 - Long spur lines to instruments and the possibility to remove/insert them during operation. Short circuit protection on each spur line is automatically provided ProfiHub B2FO2+ User Manual – v2.1.0 | 29 December 2016 | © PROCENTEC 6/38...
  • Page 8: Application Areas

    Cost Savings ProfiHub B2+FO2 Fig. 4 - Creating a fiber optic backbone increases network reliability and network overview. It is also possible to mix ProfiHubs with ComBricks ProfiHub B2FO2+ User Manual – v2.1.0 | 29 December 2016 | © PROCENTEC 7/38...
  • Page 9: Channel Structure

    If by accident on 1 channel the Direct Grounding is connected with the Indirect Grounding, the connection to the Direct Grounding bypasses the capacitor in the Indirect Ground connection. The current on the shield will flow to Direct Ground. ProfiHub B2FO2+ User Manual – v2.1.0 | 29 December 2016 | © PROCENTEC 8/38...
  • Page 10: Cable Lengths For Profibus Dp

    Capacity < 30 pF/m Loop resistance < 110 Ohm/km Wire diameter > 0.64 mm Wire area > 0.32 mm Fig. 7 - PROFIBUS DP cable specifications ProfiHub B2FO2+ User Manual – v2.1.0 | 29 December 2016 | © PROCENTEC 9/38...
  • Page 11: Cable Lengths For Fiber Optic

    Power is not switched Trying to detect the The transmission on or an internal error transmission speed, but speed has been detected has not locked it yet ProfiHub B2FO2+ User Manual – v2.1.0 | 29 December 2016 | © PROCENTEC 10/38...
  • Page 12: The Red Error Led

    It can also be that the baudrate is not locked (no PROFIBUS master on the bus) or the baudrate was set manually and incorrectly with the rotary switch. ProfiHub B2FO2+ User Manual – v2.1.0 | 29 December 2016 | © PROCENTEC 11/38...
  • Page 13: Comparison Table

    ST/BFOC, screw terminals connectors connectors and DB9 connectors Alternative connectors Termination LEDs Ground rail Redundant channel Offshore approvals None None None UL approvals None UL: ITE E365044 None ProfiHub B2FO2+ User Manual – v2.1.0 | 29 December 2016 | © PROCENTEC 12/38...
  • Page 14: Installation Instructions Profihub B2Fo2

    This is to prevent the product to potentially slide off the DIN-rail. See Fig. 9 for an example. Fig. 9 - Rubber studs on backside of housing ProfiHub B2FO2+ User Manual – v2.1.0 | 29 December 2016 | © PROCENTEC 13/38...
  • Page 15: Power Supply

    Add cable crimp terminals/wire ferrules to the conductors.  Secure the crimp terminals in the screw-type terminal. To connect the power supply, you need a 3 mm screwdriver. ProfiHub B2FO2+ User Manual – v2.1.0 | 29 December 2016 | © PROCENTEC 14/38...
  • Page 16: Grounding Of The Power

    LEDs will stop blinking. The maximum power to be connected to the alarm contact is 24 VDC. The maximum switching current is 500 ProfiHub B2FO2+ User Manual – v2.1.0 | 29 December 2016 | © PROCENTEC 15/38...
  • Page 17: Fiber Optic Backbone

    Fiber optic applications require a delay time calculation to adjust the MinTSDR and Slottime (Tslot) busparameters in the configuration of the master(s). The B2FO2+ complies with the following formulas: ProfiHub B2FO2+ User Manual – v2.1.0 | 29 December 2016 | © PROCENTEC 16/38...
  • Page 18: Spur Segments

    The termination of the Channels have been set to ON by default, because it is assumed that the new segment is started at the ProfiHub (Fig. 15). ProfiHub B2FO2+ User Manual – v2.1.0 | 29 December 2016 | © PROCENTEC 17/38...
  • Page 19: Baudrate Switch

    (Fig. 16). Baudrate switch Alarm reset button Fig. 16 - Baudrate speed switch To set the rotary switch, use a 3 mm screwdriver. ProfiHub B2FO2+ User Manual – v2.1.0 | 29 December 2016 | © PROCENTEC 18/38...
  • Page 20: Robust Repeating Mode

    (1 and 2) to be one redundant path to another B2FO2+, a B2+, to a redundant ComBricks, or to any other supporting product. See Fig. 17 for an example. ProfiHub B2FO2+ User Manual – v2.1.0 | 29 December 2016 | © PROCENTEC 19/38...
  • Page 21 Generally a MinTSDR of 25 is sufficient. If long fiber optic cables or many optical link modules (OLMs) are used, check paragraph 2.8 for an example of the MinTSDR calculation. ProfiHub B2FO2+ User Manual – v2.1.0 | 29 December 2016 | © PROCENTEC 20/38...
  • Page 22: Technical Data Profihub B2Fo2

    ≤2.2 Tbit ≤13.60 Tbit 6 Mbps ≤3.0 Tbit ≤14.00 Tbit 12 Mbps ≤4.0 Tbit ≤15.00 Tbit Delay time jitter Max. ¼ bit time Cascading depth No limits ProfiHub B2FO2+ User Manual – v2.1.0 | 29 December 2016 | © PROCENTEC 21/38...
  • Page 23 Maximum 31 per Channel (including ProfiHubs, OLMs etc) Termination Integrated and switchable. Powered according to IEC 61158 (390/220/390 Ohms) - All Channels (default on) Redundancy Yes (copper channel 1 and 2) ProfiHub B2FO2+ User Manual – v2.1.0 | 29 December 2016 | © PROCENTEC 22/38...
  • Page 24 10 mm (when the ground rail is used) Wire diameter < 2.5 mm Alarm contact Voltage Max. 24 V DC Current 0.5 A Others MTBF T.b.d. ProfiHub B2FO2+ User Manual – v2.1.0 | 29 December 2016 | © PROCENTEC 23/38...
  • Page 25: Sales Offices And Distributors

    China CZECH REPUBLIC FOXON s.r.o. T: +420 484 845 555 Polní 367 F: +420 484 845 556 460 01 Liberec 12 E: foxon@foxon.cz Czech Republic www.foxon.cz ProfiHub B2FO2+ User Manual – v2.1.0 | 29 December 2016 | © PROCENTEC 24/38...
  • Page 26 Israel ITALY PROCENTEC Italy T: +39 030 200 8610 Via Branze n. 43/45 F: +39 030 238 0059 25123 Brescia E: www.procentec.it Italy W: www.procentec.it ProfiHub B2FO2+ User Manual – v2.1.0 | 29 December 2016 | © PROCENTEC 25/38...
  • Page 27 E: intex@intex.com.pl Poland www.intex.com.pl ROMANIA S.C. SVT Electronics S.R.L. T: +40 365 809 305 Brǎila 7 F: +40 365 809 305 540331 Tg-Mure E: sajgo.tibor@svt.ro Romania www.svt.ro ProfiHub B2FO2+ User Manual – v2.1.0 | 29 December 2016 | © PROCENTEC 26/38...
  • Page 28 Synergy Controls T: +971 4 3262692 907, IT Plaza Silicon Oasis : F: +971 4 3262693 DubaiI E: sales@synergycontrols.ae United Arab Emirates UNITED KINGDOM and N. Ireland ProfiHub B2FO2+ User Manual – v2.1.0 | 29 December 2016 | © PROCENTEC 27/38...
  • Page 29 Ward 2, Tan Binh District E: hai.hoang@bavitech.com Ho Chi Minh City www.bavitech.com Vietnam For the up to date list of the Sales Offices and Distributors see www.procentec.com/company/distributors/. ProfiHub B2FO2+ User Manual – v2.1.0 | 29 December 2016 | © PROCENTEC 28/38...
  • Page 30: Order Codes

    5. Order codes Component Order code Remarks 17220 ProfiHub B2FO2+ With Alarm contact With redundant power input ProfiHub B2FO2+ ProfiHub B2FO2+ User Manual – v2.1.0 | 29 December 2016 | © PROCENTEC 29/38...
  • Page 31: Glossary

    - The first three octets of the user parameterization data are now standardized - Optionally these devices may support: - Acyclic communication (MS1, MS2) - If alarms are used, MS1 shall be supported ProfiHub B2FO2+ User Manual – v2.1.0 | 29 December 2016 | © PROCENTEC 30/38...
  • Page 32 A cable attached to a bus segment with a T-connection . Spurs are not recommended with PROFIBUS DP. They are prohibited with 12 Mbps and PROFIsafe operations. German term is "Stichleitung". Stub line See Spur line. ProfiHub B2FO2+ User Manual – v2.1.0 | 29 December 2016 | © PROCENTEC 31/38...
  • Page 33 The German PROFIBUS Organization based in Karlsruhe. Drop cable See Spur line. Reflection Part of the original signal that is transmitted back along the cable. It corrupts the original signal. ProfiHub B2FO2+ User Manual – v2.1.0 | 29 December 2016 | © PROCENTEC 32/38...
  • Page 34 Based on that belief, PROCENTEC continues to innovate and develop, which makes us the most reliable service provider and knowledge partner for our customers. We do all of this with total dedication.
  • Page 35: Revision History

    REF _Ref448397007 \n \h Fout! Verwijzingsbron niet gevonden. Added text for increasing MinTSDR in paragraph Fout! Verwijzingsbron niet gevonden. Removed Certificates, List of Distributors and Next Versions chapter Minor textual changes ProfiHub B2FO2+ User Manual – v2.1.0 | 29 December 2016 | © PROCENTEC 34/38...
  • Page 36 9. Notes ProfiHub B2FO2+ User Manual – v2.1.0 | 29 December 2016 | © PROCENTEC 35/38...
  • Page 37 ProfiHub B2FO2+ User Manual – v2.1.0 | 29 December 2016 | © PROCENTEC 36/38...
  • Page 38 PROCENTEC BV Klopperman 16 2292 JD Wateringen The Netherlands T: +31 (0)174 671 800 F: +31 (0)174 671 801 E: support@procentec.com W: www.procentec.com...

Table of Contents