3.2.7 Termination Status

Input Identifier byte: 0x14
The next input byte is to indicate the status of the termination switches on the ProfiHub channels.
Bit
Meaning
0
-
1
Channel 1 termination ON
2
Channel 2 termination ON
3
Channel 3 termination ON
4
Channel 4 termination ON
Examples:
0x3C = All terminations are ON
0x04 = Only Channel 1 termination is ON

3.2.8 Channel Status

Input Identifier byte: 0x15
The next input byte is to indicate the communication status of the individual channels.
Bit
Meaning
0
Communication on FO Channel
1
Communication on Channel 1
2
Communication on Channel 2
3
Communication on Channel 3
4
Communication on Channel 4
Examples:
0x06 = Communication on Channel 2 and Channel 1
0x01 = Communication on Channel 1

3.2.9 Fiber Optic Status

Input Identifier byte: 0x16
The next two input bytes indicate the status of the two Fiber Optic ports.
Byte 1:
Bit (1..0)
Meaning
0 dec
Fiber optic port 1 switched off
1 dec
Fiber optic port 1 signal error
2 dec
Fiber optic port 1 signal warning critical level
3 dec
Fiber optic port 1 Ok
Bit (3..2)
Meaning
0 dec
Fiber optic port 2 switched off
1 dec
Fiber optic port 2 signal error
2 dec
Fiber optic port 2 signal warning critical level
3 dec
Fiber optic port 2 Ok
Bit (5..4)
Meaning
0 dec
Ring mode off (line mode)
1 dec
Ring Failure
2 dec
Ring Ok