10. Remove nozzle from bath; air dry before re-installing onto diffuser.
11. Reinstall merchandiser.
F. Sanitizing Water Circuits:
Cleaning and Sanitizing are not required for potable water circuits. The potable water lines
should remain connected during the cleaning procedures for the concentrate circuits to avoid
contamination.
1. Disconnect concentrate container from product line.
2. Attach product line to container containing sanitizing solution mixed to mfg. recommendations
(100 ppm is recommended)
a. Using gray Shut-off, turn incoming water off.
Sanitizing solution temperature should be between 55˚ to 100˚ F (12.8˚ to 37.8˚ C).
3. Prepare enough solution to sanitize from the concentrate source to the dispenser.
OPTIONAL - using a fitment removed from a bag in box container. Attach fitment to concentrate
fitting. Prepare sanitizing solution in a container and set fitment/fitting assembly in solution.
4. Push VALVES switch at rear of unit to the ON position.
5. Press appropriate switch position, solution will begin to flow towards dispensing valve.
6. When color turns clear, concentrate line is full of sanitizer solution.
7. Wait 15 minutes.
a. Reconnect concentrate product line.
8. Purge sanitizer from line with concentrate product.
9. Purge until concentrate is flowing from dispensing valve.
10. Using gray Shut-off, turn incoming water on.
11. Taste the beverage to verify that there is no off taste.
12. Repeat for every product or as needed.
FLUSH SANITIZING SOLUTION FROM CONCENTRATE LINE AS INSTRUCTED. RESIDUAL
SANITIZING SOLUTION LEFT IN SYSTEM COULD DAMAGE LINES AND DISPENSER PARTS.