ONLY USE INTERNAL CLEANING SOLUTIONS THAT ARE APPROVED FOR BEVERAGE
DISPENSER APPLICATIONS, SUCH AS BevClean™. (NO CAUSTIC CHEMICALS SUCH AS
INDUSTRIAL KITCHEN CLEANING CHEMICALS SHOULD EVER BE USED)
C. External Cleaning:
The stainless steel dispenser and merchandiser can be cleaned by wiping with a cloth soaked
with warm cleansing detergent. Abrasive cleaning or scouring pads should not be used as they
will scratch the dispenser finish.
D. Daily Cleaning - Nozzle and Diffuser
1. Remove merchandiser by first turning cam lock counter clockwise, then push down on the top
of the merchandiser while pulling outward, and finally up and out of bottom slots.
2. Remove nozzle by twisting clockwise and pull down. Diffuser is not removable.
3. Wash nozzle and diffuser with warm water. Ensure cleaning solution is rinsed off. Residual
Solution will cause product off taste.
4. Reinstall nozzle by twisting counterclockwise while pushing up.
5. Reinstall merchandiser.
Nozzle and diffuser must be sanitized biweekly. Ensure sanitary gloves are used for this procedure.
E. Biweekly Sanitizing - Nozzle and Diffuser
1. Prepare sanitizing solution:
Prepare a 100 PPM chlorine solution or other FDA approved sanitizer with clean potable
water at a temperature of 55˚ to 100˚ F (12.8˚ to 37.8˚ C).
Comparable strength: 1/2 fluid oz. un-scented bleach in 1 gallon of water.
2. Remove merchandiser by pushing down on the top while pulling outward, then up and out.
3. Remove nozzle by twisting clockwise and pull down. Diffuser is not removable.
DIFFUSER IS NOT REMOVABLE. ATTEMPTING TO REMOVE IT WILL DAMAGE DISPENSER.
4. Inspect nozzle for cracks or breakage.
5. Wash nozzle and immerse in a container of sanitizing solution for 15 minutes.
6. Wash diffuser with warm cleaning solution and inspect.
7. Wash diffuser and sanitize
a. (OPTION 1) Use Nozzle Sanitizing Assy. (P.N. 631-0187) accessory:
Fill nozzle with sanitizing solution and install onto diffuser by twisting
counterclockwise while pushing up onto diffuser. Leave on for 15 minutes.
b. (OPTION 2) If Sanitizing Nozzle Assy. is not utilized, wash diffuser, rinse
and immerse in a sanitizing solution for 15 minutes.
8. While the parts are soaking, visually inspect around the nozzle mounting area
for syrup residue and wash area with cleaning solution.
9. Remove sanitizing nozzle from diffuser. Air Dry.
8
IMPORTANT
NOTE:
Nozzle and diffuser must be cleaned daily.
NOTE:
WARNING
P.N. 631-0187