Installation Without A - Baumatic AS35SS Instruction Manual

Hide thumbs Also See for AS35SS:
Table of Contents

Advertisement

For installation without a chimney. (Figure 5)
then level the appliance using the adjusting brackets (6 and 7).
• Lift the cover screen and mark the lower fixing point on the wall
(10). Remove the hood and drill on this marking, one hole of Ø 8
mm (9). Then insert one wall plug, hang the hood again and fasten
it securely with one screw (11).
Without a chimney the hood must
operate in recirculation mode, therefore you
should install the defector (Fig. 5a) and then
fit the carbon filter (see page 12 for details
on how to fit the carbon filter).
For ease of
mounting, trace a
central line on the wall
(1). Position the cut-
out template, so that
the middle line printed
on the top of it,
corresponds to the
central line that you
have marked
previously. The
bottom of the
template should
correspond to the
lower part of the
hood, once it is
mounted (2).
Drill two holes Ø
8 mm and fasten the
support bracket „F"
with two wall inserts
and screws (3).
Mount the hood
(5) onto support
bracket „F". You can
18