Baldor VS1STS Series Installation & Operating Manual page 45

Ac microdrive
Table of Contents

Advertisement

7.4.2 Application Specific Parameters
Par
Description
No.
Software Upgrade
P6-01
Enable
Thermal Management
P6-02
Enable
P6-03
Auto-Reset Delay Time
User Relay Speed
P6-04
Hysteresis Band
Encoder Feedback
P6-05
Enable
P6-06
Encoder PPR
Encoder Speed Error
P6-07
Limit
MN767S
Table 7-7 Application Specific Parameters
Range
0: Disable
1: I/O En
2: DSP En
0: Disable
1: Enable
1s...60
0.0 ... 25.0
0: Disabled
1: Enabled
0 .. 10000
0.0 ... 50.0
Units
Default
Enables the Application Macro
-
0
loading / firmware upgrade
process.
When set to 1, the drive will
automatically reduce the
output switching frequency
-
0
with increasing heat sink
temperature, to reduce the risk
of an over temperature trip.
Sets the delay time allowed
between consecutive reset
s
20
attempts when Auto Reset is
enabled (see P2-17).
This parameter defines a
band around zero speed as a
percentage of P1-03. When
P2-11 or P2-13 = 2 or 3, output
frequencies below this value
are treated as 'zero speed'.
This function is used to prevent
%
0.3
"chatter" on the output if the
operating speed coincides with
the level at which the digital /
relay output changes state. E.g.
if P2-13 = 3, P1-06 = 50Hz and
P6-04 = 5%, the relay contacts
close above 2.5Hz.
-
0
Enables Encoder Feedback.
Sets the number of Pulses Per
-
0
Revolution for the encoder
This parameter defines the
allowed speed error between
the encoder feedback and the
%
5.0
VS1STS own estimated rotor
speed. When set to zero, the
protection is disabled.
Parameter Descriptions 7-13
Explanation

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents