2nd Deceleration Ramp
P2-25
Time
Modbus
P2-26
Communication Baud
Rate
Drive Communication
P2-27
Address
Master / Slave Mode
P2-28
Select
Master / Slave Speed
P2-29
Reference Scaling
Factor
Bipolar Analog Input
P2-30
Format
Bipolar Analog Input
P2-31
Scaling
Bipolar Analog Input
P2-32
Offset
7-6 Parameter Descriptions
Table 7-2 Parameter Group 2 - Extended Parameters Continued
Range
0.0 to 3000.0
t9.6, t19.2, t38.4, t57.6, t115.2
r9.6, r19.2, r38.4, r57.6, r115.2
0: Disabled
1 to 63
0: Slave Mode
1: Master Mode
0 to 500.0
 2 = 0 - 24VDC
  = 0 - 10VDC
  = -10 to + 10VDC
2 2 = -24 to + 24VDC
0.0 to 500.0
-500.0 to 500.0
Units
Default
Deceleration 2nd ramp down
time
Selected Automatically on mains
power loss if P1-09 = 2
Can also be selected by digital
Seconds
0.0
inputs, dependent on P2-01
setting.
When set to 0, the drive
decelerates as quickly as
possible, while preventing an
over voltage trip.
Modbus RTU serial data link
communication Baud Rate. A
't' Prefix indicates the drive will
trip if communication with the
network master is lost, after a
Kbaud
t115.2
preset time period. An 'r' Prefix
indicates that the VS1STS will
Ramp to stop in the event of a
loss of communication with the
network master, after a preset
time period.
Sets the communication
address for the drive when
-
1
connected on a Modbus
Network.
When in Master Mode, the drive
transmits its operational status
via the serial data link. All drives
-
0
on the data link must have
unique addresses. Only one
drive can be programmed as a
Master.
Scaling factor applied to any
speed reference on the serial
data link, e.g. in Master /
%
100.0
Slave operation, a Slave drive
will apply this scaling factor to
the transmitted Master speed
reference.
Configures the analog input
signal to match the reference
connected to terminal 6. Only
-
 2
voltage signals can be directly
connected, mA reference signals
require an external 500R resistor
connection.
Scales the analog input by this
factor, e.g. if P2-30 is set for
0 – 10V, and the scaling factor
%
100.0
is set to 200.0%, a 5 volt input
will result in the drive running at
maximum speed (P1-06).
Sets an offset, as a percentage
of the full scale range of the
%
0.0
input, which is applied to the
analog input signal.