Maintenance Works
Clean the sieve in the water connection
 Take out sieve.
 Clean sieve in water and reinstall.
Cleaning the fine filter
 Unpressurize the appliance.
 Unscrew the fine filter from the boiler.
 Remove the fine filter and the filter insert.
 Clean the filter with clean water or compressed air.
 Reinstall in reverse sequence.
Clean the sieve in the safety block
 Unpressurize the appliance.
 Loosen covering nut and take off hose.
 Take out sieve.
Note: If necessary turn in screw M8 appr. 0.2 in/5 mm
inwards and therewith pull out sieve.
 Clean sieve in water.
 Push sieve inwards.
 Put on hose.
 Tighten covering nut firmly.
Clean filter at the detergent suck hose
 Take out detergent suck supports.
 Clean filter in water and reinstall.
Oil change
 Ready a catch bin for appr. 0.26 gal/1 Liter oil.
 Loosen release screw.
Dispose of old oil ecologically or turn in at a gathering
point.
 Tighten release screw.
 Fill oil slowly up to the MAX marking.
Note: Air pockets must be able to leak out.
For oil type refer to technical specifications.
Troubleshooting
DANGER
Risk of injury by inadvertent start-up of appliance and
electric shock. Prior to all work on the appliance, switch
off the appliance and pull the power plug.
Indicator lamp pump
2x blinking
Leak in the high pressure system
 Check high pressure system and connections for
tightness.
3x blinking
Lack of water after 2 minutes - the pump is
switched off to prevent dry runs.
 Check water supply, check connections.
4x blinking
Heater contactor fault
 Set the appliance switch to "0/OFF".
 Turn on the appliance.
Error occurs repeatedly.
 Inform Customer Service.
"Low water" indicator lamp
Lack of water - heater is switched off
 Check water supply, check connections.
Indicator lamp "Ready for use" turns off
No line voltage, see "Appliance is not running".
12
Indicator lamp for heater lights up
Heater operation
Engine indicator lamp
2x blinking
Engine overload/overheat
 Set the appliance switch to "0/OFF".
 Allow device to cool down.
 Turn on the appliance.
Error occurs repeatedly.
 Inform Customer Service.
3x blinking
Fault in the voltage supply.
 Check main connections and mains fuse.
4x blinking
Excessive power consumption.
 Check main connections and mains fuse.
 Inform Customer Service.
Indicator lamp boiler fault
1x blinking
Temperature limiter has got triggered.
 Set the appliance switch to "0/OFF".
 Allow device to cool down.
 Turn on the appliance.
Error occurs repeatedly.
 Inform Customer Service.
3x blinking
System care detection defective
 Inform Customer Service.
4x blinking
Temperature sensor defective
 Inform Customer Service.
Indicator lamp service
Service interval
 Perform service work.
Indicator lamp system care is illuminated
Note: Heater can only operate 5 more hours.
System care bottle empty.
 Replace the system care bottle.
Indicator lamp system care is blinking
Note: Heater operation no longer possible.
System care bottle empty.
 Replace the system care bottle.
Appliance is not running
No power
 Check power connection/conduit.
Device is not building up pressure
Air within the system
Vent pump:
 Set dosing value for detergent to "0".
 With open hand spray gun turn device on and off
multiple times with the device switch.
 Open and close the pressure/quantity regulation at
the pump unit with the hand spray gun open.
Note: By dismantling the high pressure hose from the
high pressure connection the venting process is accel-
erated.