Lincoln SKF FlowMaster II 85875 User And Maintenance Instructions
Lincoln SKF FlowMaster II 85875 User And Maintenance Instructions

Lincoln SKF FlowMaster II 85875 User And Maintenance Instructions

Advertisement

User and maintenance instructions
FlowMaster II pump
Model 85875
Date of issue
March 2016
Form number
404695A
Read manual prior to installation or use of
this product. Keep manual nearby for future
reference

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SKF FlowMaster II 85875 and is the answer not in the manual?

Questions and answers

Summary of Contents for Lincoln SKF FlowMaster II 85875

  • Page 1 User and maintenance instructions FlowMaster II pump Model 85875 Date of issue March 2016 Form number 404695A Read manual prior to installation or use of this product. Keep manual nearby for future reference...
  • Page 2: Explanation Of Safety Signals

    Contents Explanation of safety Overview signals Model 85875 is a pumping unit designed to operate a Centro-Matic lubrication system. The unit includes a vent valve to relieve line Safety ......pressure to recharge injectors.
  • Page 3: Installation

    Installation assembly (44) and the seat of pump check WARNING  disc assembly (43). Sealing surfaces of seat Before performing maintenance or ser- Locate unit so that electric and hydraulic must fully seal. vice, disconnect all hydraulic and electric power connections are accessible. power to the pump assembly.
  • Page 4: Low Level Indicator

    Safety unloader valve Low level indicator 6 Remove packing assembly(49) from cylinder (51). Refer to Fig. IPB1, pg. 6. If pressure 7 Inspect needle (52 and valve seat (53) for Refer to Fig. 3 and Fig. IPB1, pg. 6. If indi- switch fails to operate, safety unloader (1) foreign matter that may be lodged and cator pin appears to drop prematurely or...
  • Page 5 Follower Fig. 4 Follower assembly (38) Refer to Fig. 3, (pg. 4), Fig. 4 and Long Fig. IPB1, pg. 6. Service unit if follower Long bolt bolt foam is damaged or fails to wipe sides of reservoir effectively. 1 Remove bolts (4, 18) and washers (19) holding the cover on the reservoir.
  • Page 6 Fig. IPB1 20.46 in. Ø 15 (520 mm) (384 mm) Ø 13 (352 mm) Bolt hole circle Ø (12,7 mm) mounting holes (6 x) 60° apart 40° 20° 37.4 in. (950 mm) 39, 40...
  • Page 7 Table 1 Service parts Item no. Description Quantity Part no. Item no. Description Quantity Part no. Safety unloader 90942 Hex hd cap screw ( -16 x 50016 Vent itting 249354 Not used Extension tube 276853 Gasket 31029 Eye bolt ( -16) 276300 Pump check disc assembly...
  • Page 8: Lincoln Industrial Standard Warranty

    Lincoln warrants the equipment manufactu- Lincoln GmbH and Co. Kg, Walldorf, ves, 912 series lube meters, electronic lube red and supplied by Lincoln to be free from Germany, for your warranty rights. meters (980, 981, 982 series), our universal defects in material and workmanship for a...
  • Page 9 This page is intentionally blank.
  • Page 10 This page is intentionally blank.
  • Page 11 This page is intentionally blank.
  • Page 12 | lincolnindustrial.com ® SKF is a registered trademark of the SKF Group. ® Lincoln and FlowMaster II are registered trademarks of Lincoln Industrial. © SKF Group 2016 The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted.