Summary of Contents for Lincoln SKF FlowMaster II 85875
Page 1
User and maintenance instructions FlowMaster II pump Model 85875 Date of issue March 2016 Form number 404695A Read manual prior to installation or use of this product. Keep manual nearby for future reference...
Contents Explanation of safety Overview signals Model 85875 is a pumping unit designed to operate a Centro-Matic lubrication system. The unit includes a vent valve to relieve line Safety ......pressure to recharge injectors.
Installation assembly (44) and the seat of pump check WARNING disc assembly (43). Sealing surfaces of seat Before performing maintenance or ser- Locate unit so that electric and hydraulic must fully seal. vice, disconnect all hydraulic and electric power connections are accessible. power to the pump assembly.
Safety unloader valve Low level indicator 6 Remove packing assembly(49) from cylinder (51). Refer to Fig. IPB1, pg. 6. If pressure 7 Inspect needle (52 and valve seat (53) for Refer to Fig. 3 and Fig. IPB1, pg. 6. If indi- switch fails to operate, safety unloader (1) foreign matter that may be lodged and cator pin appears to drop prematurely or...
Page 5
Follower Fig. 4 Follower assembly (38) Refer to Fig. 3, (pg. 4), Fig. 4 and Long Fig. IPB1, pg. 6. Service unit if follower Long bolt bolt foam is damaged or fails to wipe sides of reservoir effectively. 1 Remove bolts (4, 18) and washers (19) holding the cover on the reservoir.
Lincoln warrants the equipment manufactu- Lincoln GmbH and Co. Kg, Walldorf, ves, 912 series lube meters, electronic lube red and supplied by Lincoln to be free from Germany, for your warranty rights. meters (980, 981, 982 series), our universal defects in material and workmanship for a...
Need help?
Do you have a question about the SKF FlowMaster II 85875 and is the answer not in the manual?