Technical Data; Wiring Diagram; Unified Wiring Diagram Legend - Daikin FTXP50M2V1B Installer's Reference Manual

Hide thumbs Also See for FTXP50M2V1B:
Table of Contents

Advertisement

11 Technical data

11.1 Wiring diagram

11.1.1 Unified wiring diagram legend

FTXP50~71M2V1B + FTXF20~71A2V1B + ATXF50~71A2V1B
Daikin room air conditioner
4P513661-8H – 2019.12
A subset of the latest technical data is available on the regional Daikin website
(publicly accessible).
The full set of latest technical data is available on the Daikin Business Portal
(authentication required).
The wiring diagram is delivered with the unit, located inside of the outdoor unit
(bottom side of the top plate).
For applied parts and numbering, refer to the wiring diagram on the unit. Part
numbering is by Arabic numbers in ascending order for each part and is
represented in the overview below by "*" in the part code.
Symbol
Meaning
Circuit breaker
Connection
Connector
,
Earth
Field wiring
Fuse
Indoor unit
INDOOR
Outdoor unit
OUTDOOR
Symbol
Colour
BLK
Black
BLU
Blue
BRN
Brown
GRN
Green
GRY
Grey
Symbol
A*P
BS*
BZ, H*O
C*
11
Symbol
Meaning
Protective earth
Protective earth
(screw)
A
Rectifier
Relay connector
Short-circuit
connector
Terminal
Terminal strip
Wire clamp
Symbol
Colour
ORG
PNK
PRP, PPL
RED
WHT
YLW
Meaning
Printed circuit board
Pushbutton ON/OFF, operation switch
Buzzer
Capacitor
Technical data
|
Orange
Pink
Purple
Red
White
Yellow
Installer reference guide
45

Hide quick links:

Advertisement

Table of Contents
loading