Mini receiver

Advertisement

Available languages

Available languages

Mini receiver RCL07
GB
Model
Cable entry
Programming
with cord grip
button with LED
TA2
RCL07E5002A21
Technical Details
Frequency:
868.3 MHz
Modulation:
FSK
Coding:
Easywave
Power supply:
12-24 V DC
Current consumption:
12 V DC:
19 mA stand by
65 mA load *)
24 V DC:
11 mA stand by
31 mA load *)
Max. contact rating:
30 V / 1 A / 30 W
Output:
2 potential-free
relay contacts (1 CO
and 1 NO)
Operating Temperature: -20 °C to +60 °C
Degree of Protection:
IP54
Dimensions (w/l/h):
35/80/20 mm
Weight:
38.0 g
Connecting cable:
Ø 5 mm
*)
Both relays are switched.
Scope of Delivery
Mini receiver RCL07, operating instructions
Intended Use
The unit may only be operated with safety extra
low voltage (SELV) and may only be used as a ra-
dio control for switching devices with safety extra
low voltage (SELV).
The manufacturer shall not be liable for any dam-
age caused by improper or non-intended use.
Safety Advice
Before using the device, carefully read
through the operating instructions!
Caution! Observe the permissible supply volt-
age and the max. contact rating!
Have faulty radio controls checked by the
manufacturer!
Do not make any unauthorized alterations or
modifications to the receiver!
Function
The RCL07 Easywave Mini-Receiver can be op-
erated in a voltage range of 12-24 V DC.
A total of 32 different Easywave radio transmis-
sion codes can be memorized.
Operating modes
Via jumper J1 you can set the operating modes.
DEAD MAN
(1-button operation)
The relay is triggered as long as the correspond-
ing transmitter button is pressed (max. 36 sec).
ON/OFF
(2-button operation)
The relay can be switched ON or OFF targeted.
The transmitter button A or C switch ON, the
transmitter button B or D switch OFF.
IMPULSE
(1-button operation)
If a transmitter button is pressed, the correspond-
ing relay is triggered for 1 second.
TA1
Start-Up
1. Remove the housing cover.
2. Select the desired operating mode with jum-
per J1. The factory setting is the IMPULSE.
3. Connect the supply voltage and the safety
extra low voltage devices to be switched as
follows:
NC1, COM, NO1, NO2:
-
+,
: Power supply 12-24V DC
4
4. Re-install the housing cover.
5. Transfer the codes of the transmitters to
the receiver (see section "Programming the
transmission codes").
The receiver cannot receive EasywePlus
telegrams, i.e. the receiver cannot be pro-
grammed with the learn button PTx of the
Easywave radio transmitter.
Caution: Make sure there is no interference with
the wireless connection. Do not mount the device
in a distribution box, in metal casings, in direct
proximity to large metal objects, on the floor or
close to it.
Programming the transmission codes
In the "Programming the transmission codes"
mode you can transfer the codes of your trans-
mitter buttons to the receiver.
The selected operating mode is adopted as a re-
sult of the memorizing process and applies to the
transmission code currently memorized.
1. Briefly (< 1.6 sec) press the programming
button TA1 for channel 1 or TA2 for channel
2. The receiver is for approx. 30 sec in the
learning mode, the corresponding channel
LED flashes.
2. DEAD MAN and PULSE: Press and hold a
transmitter button.
ON/OFF: Press and hold the transmitter but-
ton A or C. The code of the corresponding
transmitter button (B/D) will be assigned au-
tomatically.
If the code has been memorized, the LED
lights up and the receiver is going in the oper-
ating mode. Release the transmitter button.
3. Repeat step 1 and step 2 to learn in other
transmitters.
Notice: In order to change the operating mode,
first delete the transmission code then, using a
jumper to select the new operating mode and
subsequently transfer the transmission code.
If the LED flashes rapidly for approx. 4 sec, all 32
4 3 2
1
J1
memory locations are occupied.
Each type of transmitter can only be
taught-in to the RCL07 once!
4 3 2
1
If transmission code A or B has been
J1
taught-in to transmitters with 2-touch
operation for example, buttons C and D
cannot be used in this RCL07.
4 3 2
1
CO/NO
J1
3
2
1
Deleting specific transmission codes
J1
1. Press and hold the programming button TA1
for channel 1 or TA2 for channel 2 more than
1.6 sec. The LED TA1 or TA2 flashes rapidly.
The receiver is for approx. 30 sec in the erase
mode.
2. Press the selected transmitter button. When
the code has been deleted, the LED lights up
and the receiver enters the operating mode.
In the ON/OFF mode, the code of the corre-
sponding button is also deleted.
Deleting all transmission codes (Reset)
1. Keep the programming button TA1 or TA2
pressed for more than 1.6 sec. The LED
flashes rapidly. The receiver is for approx.
30 sec in the erase mode.
2. Press the same programming button again
and keep it pressed for more than 1.6 sec.
If the memory has been deleted completely,
the LED lights up and the receiver enters the
operating mode.
Notice: Canceling the learning operation and all
delete operations are possible by pressing the
button TA1 or TA2 briefly or you can wait approx.
30 sec, until the receiver is switched to the oper-
ating mode.
Disposal
Waste electrical products not be disposed of
with household waste!
Dispose of the waste product via a col-
lection point for electronic scrap or via
your specialist dealer.
Put the packaging material into the
recycling bins for cardboard, paper and
plastics.
Warranty
Within the statutory warranty period we under-
take to rectify free of charge by repair or replace-
ment any product defects arising from material or
production faults.
Any unauthorized tampering with, or modifica-
tions to, the product shall render this warranty
null and void.
Conformity
Hereby, ELDAT EaS GmbH declares that the
radio equipment type RTS40 is in compliance
with Directive 2014/53/EU.
The full text of the EU declaration of conform-
ity is available at the following internet address:
www.eldat.de
Service
If, despite correct handling, faults or malfunctions
occur or if the product was damaged, please
contact your retailer or the manufacturer.
ELDAT EaS GmbH
Im Gewerbepark 14
15711 Königs Wusterhausen
Germany
Phone: + 49 (0) 33 75 / 90 37-310
Telefax: + 49 (0) 33 75 / 90 37-90
Internet: www.eldat.de
E-mail: info@eldat.de