Change Hydraulic System Filter And Fluid - Exmark STARIS E Series Operator's Manual

Table of Contents

Advertisement

Maintenance
Change Hydraulic System
Filter and Fluid
Service Interval: After the first 250 hours
Every 500 hours/Yearly
(whichever comes
first) thereafter.
(Every 250 hours/Yearly
if using Mobil 1 15W50
thereafter)
Note: Use only Exmark Part No. 109-4180 for
Summer use above 32°F (0°C) or P/N 1-523541 for
Winter use below 32°F (0°C) (Refer to Transmission
section in Specifications for filter specifications).
1.
Stop engine, wait for all moving parts to stop, and
remove key or spark plug wire(s). Engage parking
brake.
2.
Remove the RH side guard.
1. RH side guard
3.
Place a catch pan under the hydro filter.
4.
Carefully clean area around filter. It is important
that no dirt or contamination enter hydraulic
system.
5.
Unscrew filter to remove and allow oil to drain
from reservoir.
Important: Before reinstalling new filter, fill
it with Exmark Premium Hydro oil and apply
a thin coat of oil on the surface of the rubber
seal.
Turn filter clockwise until rubber seal contacts the
filter adapter, then tighten the filter an additional
2/3 to 3/4 turn.
Figure 24
6.
Fill reservoir as stated in Check Hydraulic Oil
Level.
Exmark Premium Hydro Oil is recommended.
Refer to the chart for an acceptable alternative:
Hydro Oil
Exmark Premium Hydro
Oil (Preferred)
Mobil 1 15W50
*May need more often under severe conditions.
7.
Loosen filter 1/2 turn and allow a small amount
of oil to leak from the oil filter (this allows air to
be purged from the oil filter and supply hose from
the hydraulic reservoir). Turn filter clockwise
until rubber seal contacts the filter adapter. Then
tighten the filter an additional 2/3 to 3/4 turn.
8.
Raise the rear of machine up and support with
jack stands (or equivalent support) just high
enough to allow drive wheels to turn freely.
CAUTION
Raising the mower for service or maintenance
relying solely on mechanical or hydraulic
jacks could be dangerous. The mechanical or
hydraulic jacks may not be enough support
or may malfunction allowing the unit to fall,
which could cause injury.
g271949
Do Not rely solely on mechanical or hydraulic
jacks for support. Use adequate jack stands
or equivalent support.
9.
Start engine and move throttle control ahead to
full throttle position. Move motion control levers
inward (together) and move both levers forward
with equal pressure, and run for one minute. Shut
down the machine, allow the hydros to cool and
recheck oil level.
If either drive wheel does not rotate, one or both
of the charge pumps (located on the top of the
main pump as shown in Figure 25) may have lost
their "prime". Refer to Hydraulic System Air
Purge section.
10.
Reinstall the RH side guard.
11.
Remove the jack stands.
36
Service Interval
After first 250 hours
*Every 500 hours/Yearly
thereafter
After first 250 hours
*Every 250 hours/Yearly
thereafter