Check Safety Interlock System - Exmark STARIS E Series Operator's Manual

Table of Contents

Advertisement

Maintenance

Check Safety Interlock System

Important: It is essential that operator safety mechanisms be connected and in proper operating
condition prior to use.
Note: If machine does not pass any of these tests, Do Not operate. Contact an Authorized Service Dealer.
Check the Normal Engine Starting Chart
Service Interval: Before each use or daily
Note: It is not necessary for the operator to be on the platform to start the engine.
State of System
Up position, but blades
*Note: The starter will crank with the PTO switch in the "ON" (pulled up) position; however, the system will
disengage the PTO and a reset PTO error will occur. Engaging the PTO will require the operator to reset the
PTO switch by turning it "OFF" (pushed down) and then turning it "ON".
Check Engine Starting Circuit Chart
Note: In the Check Engine Starting Circuit Chart, the state of system item that is bold is being checked
in each scenario.
State of System
PTO (Blades)
Disengaged
disengaged*
PTO (Blades)
Disengaged
Engaged
System
Motion Control Levers
Both levers out (neutral)
Both levers out (neutral)
System
Motion Control Levers
Both levers not in neutral
Both levers in neutral
32
Outcome
Starter should crank
Starter should crank
Outcome
Starter must not crank
Starter must not crank