Summary of Contents for Norac UC5 CAN BUS Case IH 20 Series
Page 1
Case IH 20 & 30 Series Active Wing Roll Control Option Installation Manual 5466BC-CS...
Page 2
Reorder P/N: 5466BC-CS-INST Rev C (Case IH 20 & 30 Series Active Wing Roll Control Option) NOTICE: NORAC Systems International Inc. reserves the right to improve products and their specifications without notice and without the requirement to update products sold previously. Every effort has been made to ensure the accuracy of the information...
1 Introduction Congratulations on your purchase of the NORAC UC5 Spray Height Control System. This system is manufactured with top quality components and is engineered using the latest technology to provide operating reliability unmatched for years to come. When properly used the system can provide protection from sprayer boom damage, improve sprayer efficiency, and ensure chemicals are applied correctly.
Follow the installation instructions in Section 4.1. If the sprayer only has one set of brackets near the end of the booms, a bracket kit is needed to complete the installation. The following kit is available from NORAC. Follow the installation instructions in Section 4.2.
Page 8
P - PIPE Do not use high speed power tools/drills when installing hardware. The use of dielectric grease is not recommended on any NORAC electrical connections. To ensure all stainless steel hardware does not gall or seize apply a light coating of the supplied Permatex Anti-seize grease to all threaded parts upon installation.
Component failure due to oil contamination is not covered under the NORAC UC5 system warranty. It is recommended that a qualified technician perform the hydraulic installation.
Page 10
(Figure 5) and it has plugs installed in the bolt holes where the expansion block would typically mount onto the block (Figure 6), contact NORAC for a replacement block. 2. Remove the four 4MBP plugs from the 3 station valve block (Figure 7). Gently tap the plugs with a hammer to loosen before attempting to remove.
Page 11
3.3 Wing Roll Cylinder Mounting 1. Install the wing roll cylinder mounting bracket (B07 and B08) ont the boom frame using the supplied hardware (M9-M12). Tighten hardware to 30-40 ft-lb (41-54 Nm). 2. Mount the wing roll cylinder (H20) to the bracket using the supplied clamps. Install the WRC with the cable end pointing towards the right-hand wing (when looking from the rear of the sprayer).
Page 12
From this point on in the installation the booms will be inoperative until the hydraulics are fully installed. After the NORAC valve is mounted, the hydraulic hoses and fittings can be plumbed. The plumbing for the hydraulic circuit is shown schematically in Figure 2.
7 and 8. 2. Connect the 2 pin connector on cables C10 into positions 7 and 8 on the valve module. Connect the other end of cables C10 to the 2 pin connectors on the NORAC expansion block (V02).
Page 14
4. Connect the WRC (H20) to the 8-way coupler (E11) where one of the roll sensors was connected. Figure 12: Electrical Installation of Valve Cables (C10), WRC (H20) and 6-Pin Plugs (P03)
Page 15
4.1 Sensor Installation with an Existing Severe Terrain Option 1. Remove the inner height sensors from the brackets. Keep these sensors as spares. 2. Install the sensors (E07) into the brackets with the lower serial number on the left (Figure 13).
Page 16
3. The outer wing sensors will have been installed with either a 2-way coupler with terminator (NORAC part number 43764T [E20]) or a 3-way coupler and a terminator plug (NORAC part numbers 43760 and 43764 [E10 & E20]). Determine which type is installed and follow the appropriate set of instructions.
Page 17
4.2.2 Installation with 3-Way Coupler and Terminator Plug 1. Remove the terminator plug (E20) from the existing 3-way coupler installed at the outer sensor. 2. Install the 3-way coupler (E10) at the inner sensor. Plug the terminator plug (E20) and the sensor cable into the 3-way coupler.
Move the left tilt cylinder full stroke three times. b) Move the right tilt cylinder full stroke three times. 2. The NORAC screen on the VT or PULSE must be used to remove air from the roll channel: a) Start an Automatic Install.
Page 19
5.2 Using an AgLeader Proprietary Display This section is only for AgLeader displays with the UC5 on the proprietary display. If the UC5 is operating on the VT within the AgLeader screen, follow the procedure in Section 5.1. 1. Remove the air from the tilt cylinders, using the sprayer’s joystick controls. a) Move the left tilt cylinder full stroke three times.
2. Mount the sensor brackets onto the boom half way between the tip and center of the sprayer. 3. Mount the NORAC ultrasonic sensor into the sensor bracket and run the sensor cable either through hole in the back or through the side cut-out and behind the bracket. Ensure...
Page 24
A problem can arise if a sensor is not mounted correctly. It is possible for the sensor to read off of the boom instead of the ground. This may only become apparent once the control system is switched from soil to crop mode. Also be careful that the sensor bracket does not collide with any other part of the boom when the boom is folded to transport position.
Page 25
TOPCON Agriculture Canada 3702 Kinnear Place Saskatoon, SK S7P 0A6 TOPCON Agriculture Americas W5527 Hwy 106 Fort Atkinson, WI 53538 TOPCON Precision Agriculture Europe Avenida de la industria, 35, Tres Cantos, España Spain Support Phone: 888 979 9509 E-mail: tasupportn@topcon.com Web: www.norac.ca...
Need help?
Do you have a question about the UC5 CAN BUS Case IH 20 Series and is the answer not in the manual?
Questions and answers