Alarm in connection.
The 25-pin D-type connectors are used to input alarm signals.
Pin 1-10 correspond to 10 channels CH1 – CH10.
Pin 11-13 are not connected.
Pin 14-25 is common (GND).

Emergency Alarm connection

Use the 6.3mm cable to connect the ALARM OUT to REMOTE IN of an emergency alarm generator. As soon
as the Alarm Matrix receives an alarm signal, the ALARM OUT will send an alarm signal to activate the
emergency alarm.

Output connection.

Use only 100V speakers or use low impedance speakers with matching 100V transformers if you're using 100V
amplifiers. If you're using low impedance amplifiers us only low impedance speakers. Never mix them up. If
you're not sure ask a qualified technician.