Related Constants For The Di-16H2 - YASKAWA Varispeed DI-16H2 Instructions Manual

Digital speed reference card
Hide thumbs Also See for Varispeed DI-16H2:
Table of Contents

Advertisement

8

Related Constants for the DI-16H2

Operator
Operator
function
display
display
Sequence
Reference
Source
Monitor
Display
Select
Scaling
DI-08, 16
DI Input
Setup
Monitor
Frequency
Ref
Table 5 Related Constants
Constant
Name
No.
b1-01
Frequency
reference
selection
o1-03
Frequency
units of refer-
ence setting
and monitor
F3-01
Frequency
reference set-
ting option
U1-01
Frequency
reference
Setting
Factory
Change
Range
setting
during
operation
0 to 3
1
No
0 to
0
No
39999
0 to 7
0
No
22
Description
0: Operator
1: Control circuit terminal
2: Communications
3: Option card
0: 0.01 Hz
1: 0.01%
2 to 39: r/min (setting the number
of motor poles)
40 to 39999: Refer to Table 4 in
Chapter 7.
0: BCD input 1%
1: BCD input 0.1%
2: BCD input 0.01%
3: BCD input 1 Hz
4: BCD input 0.1 Hz
5: BCD input 0.01 Hz
6: 5 disit BCD input
7: Binary input
Display units are determined by
the o1-03 setting.