YASKAWA Varispeed DI-16H2 Instructions Manual page 21

Digital speed reference card
Hide thumbs Also See for Varispeed DI-16H2:
Table of Contents

Advertisement

Inverter constant
Switch S1
setting
selection
o1-03
F3-01
40 to
12 bit
X9999
(X = 0-3)
*3
16 bit
X1000
16 bit
(X = 1-3)
* 1. Setting ranges when the maximum frequency (E1-04) is set to 400 Hz and the frequency ref-
erence upper limit (d2-01) is set to 110%.
* 2. Set the number of motor poles to o1-03 (Frequency units of reference setting and monitor).
Output frequency (F) is output in [reference setting (r/min
* 3. Setting example of o1-03
If setting 12000 to o1-03, reference input at 100% is 2000 and monitor display is 200.0.
Table 4 Digital Reference Selection(cont'd)
Reference input mode
3 digit BCD, signed
100%/o1-03 setting (1-4) digit
4 digit BCD, signed,
100%/o1-03 setting (1-4) digit
4 digit BCD, signed
100%/1000
• Upper limit for setting range ≤ the maximum frequency (E1-04) ≤ the frequency reference upper limit
(d2-01).
• Lower limit for setting range ≥ the minimum frequency (E1-09) ≥ the frequency reference lower limit
(d2-02).
• For BCD inputs, most upper digit can be set from 0 to 15.
Reference setting range
–1599 to +1599
–9999 to +9999
(o1-03 = 9999)
–1000 to +1000
-1
) × (o1-03 setting)/120].
21
7 Digital Reference Selection
*1
Monitor (U1-01)
display units
o1-13 = 0
o1-13 = 1
(1)
(1)
o1-01 setting fifth
digit
X = 0: units of 1
X = 1: units of 0.1
X = 2: units of 0.01
X = 3: units of 0.001