Testing
To perform the A1LB, A2LB, and the A5LB loopback test procedures:
1
Send the inband Arming and NI LPBK code 11000 to the H2TU-C-231 for at least 5 seconds.
2
Monitor the output of the H2TU-C-231 for the return of the pattern. Return of the pattern indicates one of the
following:
The H2TU-R has looped up (if the SMJK Loopback option is enabled).
An external NID has looped up (if the SMJK Loopback option is disabled), and the H2TU-C and
H2TU-R have been armed.
3
Verify, if possible, that the H2TU-R Loopback LED is either flashing yellow at four times per second
(indicating that the system is armed), or is a steady yellow (indicating that it is both armed and in SMJK
loopback). The H2TU-C Status LED also flashes yellow when the system is armed.
If the Arming code is not returned after 5 seconds, the system may be armed, but there is no
active loopback.
4
Once armed, the H2TU-C-231 can be looped back by sending Intelligent Office Repeater (IOR) LPBK
activation code 1101-0011-1101-0011 (D3D3) for at least 5 seconds. You should observe the following
activation response pattern in the order presented:
a
2 seconds of AIS (all ones pattern)
b
2 seconds of returning data pattern
c
Logic errors (including the frame bit) occurring in the returned pattern comprising:
231 errors, if IOR LPBK (H2TU-C) was sent
20 errors, if ILR-2 (H2TU-R) was sent
d
Normal looped data
This error pattern repeats every 20 seconds as long as the IOR loopback pattern is being sent. This also applies
to ILR, Time-Out Override, and Query commands.
The H2TU-C is now in logic loopback if the IOR NLOC loopback command was sent. The Time-Out
Override command or a Loopdown command can override the selection made for the loopback time-out (see
"Setting the Loopback Time-Out Option" on page
(D5D6) is received after activating a loopback, then the automatic timed expiration of the loopback is
inhibited. If this Time-Out Override is sent, then the only way to loop the H2TU-C-231 down is to do one of
the following:
Issue the Intelligent Repeater (IR) loopdown (LPDN) code 1001-0011-1001-0011 (9393).
Issue the NI LPDN and Disarm inband code 11100 or the ESF-DL code (FF24).
The Time-Out Override function is only valid for the current active loopback. The automatic
time-out timer is restored during subsequent loopback sessions.
5
Once the test is complete, do one of the following:
If the system is to loop down but remain Armed, send the IR LPDN code.
If all the equipment is to be looped down, disarmed, and returned to normal operation, send the disarm
inband code 11100 or the ESF-DL code (FF24).
50
46). If the Time-Out Override code 1101-0101-1101-0110