LTPH-UM-1109-01, Issue 1
Table 6. H2TU-C-231 List 2 ADC Config Menu Options (Continued)
Front Panel
ADC Config Menu
Display
Options
Code
DS1 BER
DBER
Threshold
See
"DS1 BER
(DBER) Option"
on page
21.
HDSL2 BER
HBER
Threshold
See
"HDSL2 BER
Threshold (HBER)
Option" on
page 21
and
"System Alarm
Output Pins" on
page
58.
Special Loopback
SPLB
Mode
SmartJack
LPBK
Loopback
Minor Alarm
ALM
Remote
RDA
Disconnect Alarm
DS1 Line Coding (DS1) Option. The DS1 line code option should always be set to conform to the type of
DS1 service (AMI or B8ZS) being provided by the HiGain HDSL2 system. The Auto mode, which can adapt to
either AMI or B8ZS, should only be used in applications that require it (such as when HiGain HDSL2 acts as a
standby circuit to DS1 circuits whose line codes are not known or may be both AMI and B8ZS). This is because
the Auto mode induces one BPV in the DS1 bit stream whenever it switches from AMI to B8ZS. The Auto mode
allows both the H2TU-C and the H2TU-R to set its DS1 output code to that which is being received at the distant
end DS1 input. This forces the input and the output codes in each direction of transmission to be identical.
H2TU-C-231 List 2
Selection
Description
ENA
Enables the fixed 24-hour DS1 BER threshold.
DIS
Prevents the generation of a system alarm due to DS1 BER.
1E-6
System alarm relay contact closes and the Status LED flashes red when the
Block Error Rate exceeds 10
1E-7
System alarm relay contact closes and the Status LED flashes red when BER
exceeds 10
NONE
Prevents generation of a system alarm due to BER.
GNLB
Configures the HiGain HDSL2 system to respond to the generic inband
loopback codes.
A1LB and
Configures the HiGain HDSL2 system to respond to the inband loopback
A2LB
codes of the Westell addressable repeater.
A3LB
Configures the HiGain HDSL2 system to respond to the inband loopback
codes of the Wescom addressable repeater.
A4LB
Configures the HiGain HDSL2 system to respond to the inband loopback
codes of the Wescom Mod 1 addressable repeater.
A5LB
Configures the HiGain HDSL2 system to respond to the inband loopback
codes of the Westell Mod 1 addressable repeater.
ENA
Enables the HiGain HDSL2 system to recognize all inband SmartJack (SMJK)
loopback commands.
DIS
Configures the HiGain HDSL2 system to ignore all inband SmartJack
loopback commands.
ENA
Enables the generation of the output alarm on pins 20 and 21 when a system
alarm condition occurs.
DIS
Disables the generation of the output alarm on pins 20 and 21 when a system
alarm condition occurs.
ENA
Enables a remote DS1 LOS condition at the input to the H2TU-R to generate
an LOS alarm. AIS or LOS (depending on ALMP) is sent towards the network.
DIS
Prevents a remote DS1 LOS condition at the input to the H2TU-R from
causing an LOS alarm. The front-panel Status LED still flashes red and the
ALRM RLOS message displays, but the alarm relay contacts do not close and
LOS is sent towards the network from the H2TU-C instead of AIS.
January 9, 2002
-6
.
-7
.
Provisioning