Xy Unit : Replacing (Replacing Kit) The Valve (For Selecting The Nozzle, For The Cylinder) - Panasonic CM202 Series Maintenance Manual

Modular high speed placement machine
Table of Contents

Advertisement

Check Every 12000 Hours (Once Two Years)
1-8-2
XY Unit : Replacing (Replacing Kit) the Valve (For Select
ing the Nozzle, For the Cylinder)
Tools
Philips driver, allen wrench
The bad motion owing to the abrasion of the valve leads to the bad motion of the cylinder, and
occurs the miss of the picking and mounting. So regular replacement is required.
444C-436P
444C-437P
444C-412E
To the next page
Page 1-88
Required time
1.
Turn OFF the power.
2.
Release the main air.
3.
Remove the head cover.
∗ Remove the screw setting the head cover by
using the philips driver.
Screw
Philips driver
Head cover
30 minutes