Rebooting A Chassis Module From The Smc Sdi Cli; Comlog - Fortinet FortiGate-7000E Series System Manual

Hide thumbs Also See for FortiGate-7000E Series:
Table of Contents

Advertisement

FortiGate-7040E management module
Chassis slot number
Management module
3
1
2
4
You can use the IPMB address or chassis slot number to reference a chassis slot when entering commands in the
management module CLI. For example, enter either of the following commands to display sensor readings for the FIM
module in slot 2:
sensor 0x84
sensor 2
When command syntax descriptions in this chapter include the
to 4) or an IPMB address number (0x82 to 0x88)

Rebooting a chassis module from the SMC SDI CLI

A common use of the SMC SDI CLI is being able to remotely reboot a FIM or FPM module.
From any SMC SDI CLI use the following command to reboot the module in slot 3:
mc reset 3 warm
Use the following command to power off the module in slot 4:
fru deactivate 4
Use the following command to power on the FIM module in slot 2 (IPMI address 0x84):
fru activate 0x84
Use the following IPMI command to reset the module SMC to reboot the module in slot 3:
sudo ipmitool -I lanplus -H 10.160.19.30 -k gkey -U admin -P admin -t 0x86 mc reset warm
Use the following IPMI command to power off the module in slot 4:
sudo ipmitool -I lanplus -H 10.160.19.30 -k gkey -U admin -P admin -t 0x88 picmg deactivate 0
Use the following IPMI command to power on the FIM module in slot 2 (IPMI address 0x84):
sudo ipmitool -I lanplus -H 10.160.19.30 -k gkey -U admin -P admin -t 0x84 picmg activate 0

Comlog

All module SMCs include a comlog system for writing and saving console log messages. When enabled, the comlog
saves log messages in a local comlog file. Log messages include all local host console messages including BIOS boot
up messages. In the comlog these messages include the following headers:
FortiGate-7040E System Guide
Name
MGMT
FPM3
FIM1
FIM2
FPM4
<slot> variable you can replace it with a slot number (1
IPMB Address (FRUID)
0x20
0x86
0x82
0x84
0x88