FortiGate-7040E management module
By default when the chassis first starts up Console 1 is connected to the FortiOS CLI of the FIM module in slot 1 and
Console 2 is disconnected.
The default settings for connecting to each console port are: Baud Rate (bps) 9600, Data bits 8, Parity None, Stop bits
1, and Flow Control None.
The FIM and FPM modules use the standard FortiOS CLI. The SMC SDI CLIs are described in this chapter.
You can use the console connection change buttons to select the CLI that each console port is connected to.
Press the button to cycle through the FIM and FPM module FortiOS CLIs and disconnect this console.
l
Press and hold the button to connect to the management module SMC SDI CLI. You can also cycle through each
l
module's SMC SDI CLI if they are enabled.
The console's LEDs indicate what it is connected to. If no LED is lit the console is either connected to the management
module SMC SDI console or disconnected. Both console ports cannot be connected to the same CLI at the same time.
If a console button press would cause a conflict that module is skipped. If one of the console ports is disconnected then
the other console port can connect to any CLI.
If you connect a PC to one of the management module console ports with a serial cable and open a terminal session
you begin by pressing Ctrl-T to enable console switching mode, then you can do the following:
Press Ctrl-T multiple times to cycle through the FIM and FPM module FortiOS CLIs (the new destination is
l
displayed in the terminal window). If you press Ctrl-T after connecting to the FPM module in slot 6 the console is
disconnected. Press Ctrl-T again to start over again at slot 1.
Press Ctrl-R multiple times to cycle through the FIM and FPM module SMC SDI CLIs if they are enabled (the new
l
destination is displayed in the terminal window). After cycling through all of the enabled SMC SDI CLIs the next
press of Ctrl-R disconnects the console port.
Once the console port is connected to the CLI that you want to use, press Enter to enable the CLI and log in. The
default administrator account for accessing the FortiOS CLIs is
account for the SMC SDI CLIs is
When your session is complete you can press Ctrl-T until the prompt shows you have disconnected from the console.

Connecting to the FortiOS CLI of the FIM module in slot 1

Use the following steps to connect to the FortiOS CLI of the FIM module in slot 1:
1. Connect the console cable supplied with your chassis to Console 1 and to your PC or other device RS-232 console
port.
2. Start a terminal emulation program on the management computer. Use these settings:
Baud Rate (bps) 9600, Data bits 8, Parity None, Stop bits 1, and Flow Control None.
3. Press Ctrl-T to enter console switch mode.
FortiGate-7040E System Guide
Each module, including the management module, includes an SMC SDI console. These
consoles are used for low level programming of the module using an IPMI tool and are
disabled by default. You can enable serial access to individual module SMC SDI consoles
from the management module SMC SDI CLI using the command
enable <slot> . During normal operation you may want to access the management
module SMC SDI CLI, you shouldn't normally require access to individual module SMC SDI
consoles.
admin / admin .
admin with no password. The default administrator
serial set sdi