1.

General Safety Instructions

Before putting the bed into operation, it is very important that this User Manual is read carefully. The manual
contains important information for safe and proper use of the bed. Keep this manual handy for future
reference.
All of the functions of this bed should be fully tested by a competent person before the bed is used.
The bed must not be used if faults have been detected that may injure the patient/user or cause damage to the bed or
the surrounding furniture.
The operating persons are obliged to acquaint the patient lying on the bed with the control functions that are designed
for use by the patient, and their safe usage.
The operating person is obliged, before using the bed, to be confident of the functionality and safe usage of the bed.
The bed may be used only on even and solid floors.
The bed must never be overloaded. Maximum working load - 180 kg (28.3 stones).
If there is a patient on the bed, castors must be locked (with the exception of when travelling with the bed). An
unlocked bed poses risk of injury to the patient when leaving the bed or when supporting themselves.
The height of the mattress platform must be adjusted according to the height and condition of the patient.
This is a single patient bed; no other people should sit on the bed.
When handling the moving parts of the bed, ensure that the patient, other people or objects do not become trapped.
Before cleaning or maintaining the bed, the mains power cable must be disconnected from the mains.
The bed should not be used where there is a danger of explosion or in the presence of flammable anaesthetics.
When maintaining and cleaning the bed in the space between the undercarriage and mattress platform, the profiling
functions on the handset must be locked to avoid unintentional activation of the mattress platform.
The mains power cable must be stored neatly so it does not get wound around or trapped between the moving parts
of the bed. If the mains power cable is damaged there is a serious danger of injury from electrical current.
Inspections should be made at least once a month for visible wear and tear of all moving parts of the bed and cables.
The bed is intended for adults from 12 years of age. Ensure that children only have access to the bed under
adequate supervision. Do not allow children underneath the bed at any time.
2.

Features

The drivers for the adjustment are electric mechanical linear motors with maintenance free permanent lubrication.
The motors are operated by a handset connected to the main control box via a spiral wound cable.
The motors and handset are isolated from mains voltage (230v) and operated at DC 24v low voltage.
3.

Installation

The bed should only be assembled by a suitably competent person. The bed is suitable for installation by one
person. When installing more than five beds, two people should be used to complete the installation. They must read
and fully understand all of the instructions contained in this user manual. Do not attempt to assemble this bed if you
are unsure about any part of the instructions, or if any damage or defect can be identified.
The fuse in the mains plug should not exceed 5 amps.
The bed should be located on a level flat surface. Do not site the bed on loose carpet, rugs or floor coverings.
The cable from the mains power supply plug to the main control unit must be positioned clear of the lift mechanism
and braked castor system to eliminate the danger of shearing or crushing the cable.
Ensure that all cable conduits are fully secured.
3
9
Troubleshooting
Fault
1) No power supply – Plug power cable into mains socket and turn on.
One or more motors not working
when handset operated or the
2) Check the handset, motor and main control box connections.
handset does not function.
3) Motor or handset defective - Contact Park House Healthcare Ltd.
Motors suddenly have no response
1) Switch off and unplug the mains cable; plug it back in and switch on.
or movement.
2) Leave the system in the rest position for approx. 20-30 min and retry.
3) Contact Park House Healthcare Ltd.
WARNING - Any unauthorized modifications, adjustments or alterations will result in warranty invalidation. All repairs
must be carried out by a suitably qualified competent engineer.
10.
Technical data / spare parts
Overall length:
2145 mm (inc. Head and footboard brackets)
Overall width:
900 mm without side rail
Adjustable platform height:
170 mm (low position) / 710 mm (high position)
Clearance beneath the bed:
135mm
Safe working load:
180 kg (28.3 Stone) under normal condition
Weights:
Head section:
26.8 kg (inc head motor & knee motor)
Scissor section:
47.0 kg (inc main motor)
Side rails (Pair):
15.0 kg
Total bed weight: 95.5 kg (without side rails, mattress or accessories)
Control Box ref:
CB9160AE4+A0013
Main motor ref:
31111S+1022502H
Backrest motor ref:
31250C+2110002F
Knee motor ref:
312110+2005002F
Adjustment for backrest / Adjustment for thigh rest:
H
a
n
d
s
t e
e r
: f
H
B
7
X
2
4
3
0 -
0
Battery backup ref:
BA1812+0400+000 24VDC 10A
Product conforms to IEC 60601-2-52
Park House Healthcare Ltd reserves the right to make technical changes, specification amendments and product
improvements without notice.
BATTERY
As per the Batteries and Accumulators (Placing on the market) Regulations, Park House Healthcare Ltd will take back
the battery from this equipment free of charge at the end of its life.
Our battery producer registration number is BPRN00892.
Park House Healthcare Ltd reserves the right to make technical changes, specification amendments and product
improvements without notice.
Action
Platform length:
1020 mm with side rails
Platform width:
Castors: 75mm Diameter
Central locking at foot end
Foot section:
18.4 kg
H/F boards
3.2 kg each
Input 230V / 50Hz
Output: 24V DC Max 1.5A
Actuator force: Push 6000N
Power: 24Vm Max 4.3
Actuator force: Push 3500N
Power: 24Vm Max 3.9A
Actuator force: Push 4000N
Power: 24Vm Max 3.8A
66 deg +/- 2 deg / 13 deg +/- 2 deg Adjustment for calf rest: 9.5 deg
M
t o
r o
P I
R
t a
n i
: g
A
l l
a
e r
a r
e t
d
P I
6
Power duration:
Max. 10% (2 mins per 18 mins)
8
1980 mm
880 mm
6