5) Setting Function; Function - SunStar SJS/A-BA2 User Manual

Direct-drive, automatic 2-needle belt loop sewing machine
Hide thumbs Also See for SJS/A-BA2:
Table of Contents

Advertisement

4.8.5) Setting function

The test item setting enables the measuring of the time taken for forward and backward movement of the feeding and
clamp parts.
[set] on the left is a default value and [time] on the right is the current time. If the difference between [set] and [time] is
significant, the speed can be adjusted with the pneumatic valve.
※ AIR should be "ON."
① When (ENTER) is pressed, it moves forward. When
(ENTER) is pressed again, it moves backward.
② Whenever (ENTER) is pressed, feeding time appears.
③ Press the UP/DOWN key to select items from No. 1 to
No. 4.
■ Setting Details
No
1
Forward time of supplier
2
Forward time of clamp
3
Short forward time
4
Ready motion time

4.9) Function

Function is used to change parameter values.
4.9.1) Function
① While the power is off, press the (No) key and the
(Speed) key at the same time and turn on the power.
② Use the UP/DOWN keys to select an item and press the
(ENTER) key. The value is automatically filled. When
the (ESC) key is pressed, the value is not automatically
filled.
(When the Enter or ESC key is pressed, the screen
below appears.)
③ Turn off the power.
Operation 1
Operation 2
Backward time of supplier
Short backward and return time of clamp
Return time
1Cycle motion time
/
39

Advertisement

Table of Contents
loading

Table of Contents