Connecting to the DTE (Router or FRAD)
1. Connect the appropriate cable to the Port connector.
– If the DTE interface type is EIA-530A, the DTE can be directly connected to the
Port connector.
– If the DTE interface type is V.35 or X.21, a V.35 or X.21 adapter cable is
required.
2. Plug the other end of the cable into the DTE.
3. Tighten the screws on each side of the connector to secure them.
Verification Check:
Is the Port OK LED on?
– If yes, the port is set up correctly and is operational.
– If no, check that both ends of the cable are properly seated and secured.
Check Health and Status messages in the left column of the System and Test
Status screen for messages.
Main Menu
– If System Operational appears, the Port interface is set up correctly and
is operational.
– If System Operational does not appear, refer to the status information in
Displaying System Information of the User's Guide.
NOTE:
When any error conditions are detected, a status message appears along the
bottom right corner of the screen.