Setting Up Service Provider Connectivity
at the Central Site
When management needs to be set up between a service provider's customer and its
network operations center (NOC), a non-multiplexed DLCI must be configured to carry
management data between the customer's central site and the NOC console. This
requires that a frame relay discovered DLCI needs to be modified. This is because all
auto-configured network DLCIs are configured as multiplexed DLCIs.
To set up NOC management:
1. Select DLCI Records on the network interface:
Configuration
2. Select Modify. The Modify DLCI Record for DLCI Number? prompt
appears.
3. Select the DLCI that will be used by pressing the spacebar until the correct DLCI
number appears, then select it.
4. Change the DLCI Type from Multiplexed to Standard.
The
DLCI in connections. Update DLCI usage as follows: prompt
appears.
5. Select the Delete EDLCI Connections and Make a Mgmt Only PVC
option.
PVC connections for the selected DLCI are broken, the Port-1 DLCI mapped to
this network DLCI and the embedded management DLCI (EDLCI) are deleted, and
the selected DLCI will be reconfigured as a management PVC using the Node IP
Address.