Industrial Scientific AirAware Instruction Manual

Stationary gas monitor

Advertisement

P/N 6700-1347
REV 2 Printed 0604-1000
Specifications Subject to Change
1001 Oakdale Road, Oakdale, PA 15071-1500
(412) 788-4353 • Toll Free 1-800-DETECTS
FAX 412-788-8353 • Service Dept. 1-888-788-4353
Stationary Gas Monitor
AirAware
Instruction
Manual

Advertisement

Table of Contents
loading

Summary of Contents for Industrial Scientific AirAware

  • Page 1 Stationary Gas Monitor AirAware P/N 6700-1347 REV 2 Printed 0604-1000 ™ Specifications Subject to Change 1001 Oakdale Road, Oakdale, PA 15071-1500 (412) 788-4353 • Toll Free 1-800-DETECTS FAX 412-788-8353 • Service Dept. 1-888-788-4353 Instruction Manual...
  • Page 2 OUR MISSION Design - Manufacture - Sell: Highest quality products for the preservation of life and property. Provide: Best customer service available.
  • Page 3 Dear Valued Customer: Thank you for buying and using the Industrial Scientific AirAware ™ Gas Monitor. The AirAware ™ can be relied upon for dependable service, day after day. It has been designed, manufactured, tested and proven under the most scrutinizing conditions possible.
  • Page 4: Table Of Contents

    ABLE OF ONTENTS ARNINGS AND AUTIONARY TATEMENTS ARNINGS AND AUTIONARY TATEMENTS Failure to perform certain procedures or note certain conditions may ONFIGURATIONS impairr the performance of the instrument. For maximum safety and NPACKING NSTRUMENT performance, please read and follow the procedures and conditions &...
  • Page 5: Unpacking The Instrument

    States and Canada, or (412) 788-4353. & I OUNTING NSTALLATION The mounting height of the AirAware is dependent on the gas being monitored and the source of the gas. General mounting guidelines are as follows: Heavier Than Air Similar To Air...
  • Page 6: Wiring

    IRING PERATION Connect only to Class 2 power supply through approved conduit and All AirAware versions operate on 12-24 VDC. The Monitor enclosures in accordance with local authorities having jurisdiction. version includes a 120 VAC power pack for North American electrical sockets (not included in the...
  • Page 7: Set - Up Mode

    RESET instrument faceplate simultaneously for 5 seconds. The AirAware™ is a very flexible gas-monitoring instrument "Bump" will appear in the display indicating the with many options. Listed below are the various programming instrument is now in the Set-up Mode. At this point the modes and procedures required to select various options.
  • Page 8: Bump Testing

    ESTING MODE ACTIONS TAKEN This mode disables the audio* and visual alarms, relay BUMP Disables: • Visual alarms outputs*, and freezes the analog output* at 3.0 mA for all • Audio alarm* gases except oxygen, which goes to 16.0 mA. In this •...
  • Page 9: High Alarm Set-Up

    Decimals are automatically placed as needed. If the LARM buttons are pressed during this time, the display This adjustment affects the high alarm visual indicator, on- reverts to a continuous numeric reading, which indicates board audible alarm* and high alarm relay contact*. the changed setting.
  • Page 10: Display Type

    Once the concentration of gas exceeds the preset alarm newly selected value. Five seconds after the last level, the AirAware will alarm. In all versions the visual keystroke the scrolling message commences with the alarm indicators will activate and the LED will flash once newly selected setting.
  • Page 11: Mod Bus Interface

    Although field programmable the factory alarm set points are as follows: NTERFACE The AirAware is a ModBus RTU compliant instrument. LOW ALARM HIGH ALARM Please consult the factory for detailed information of 35 ppm 70 ppm ModBus registers. 0.5 ppm 1.0 ppm...
  • Page 12: Zeroing

    EROING of the zero process, the word "PASS" or "FAIL" is Zeroing an AirAware is the act of setting the instrument to displayed for 5 seconds along with a .25 second audible read either 000 ppm or 00.0 ppm (20.9 for oxygen) in a beep, after which time the unit reverts to the normal gas/hazard-free environment.
  • Page 13: Sensor Replacement

    ENSOR EPLACEMENT • After the unit fiinishes auto-zeroing, it will display either Occasionally, AirAware sensors will need to be replaced. PASS or FAIL. If teh sensor passes the zeroing function, Repeated failures of zero, calibration, and bump tests can switch gas cylinders and connect the calibration adapter be indications that the sensor has degraded.
  • Page 14: Specifications

    PECIFICATIONS 7.2" x 5.6" x 1.6" (18.29 cm x 14.22 cm x 4.06 cm) 17 oz. (482 grams) EIGHT 4 digit high resolution bright led ISPLAY Two 5-amps 30 VDC, NO and NC ELAY ATING 4-20 mA three-wire interface NALOG UTPUT 1000 ohms @ 24 VDC 500 ohms @ 12 VDC...
  • Page 15: Replacement Parts & Accessories

    ALIBRATION EPLACEMENT YLINDERS Industrial Scientific offers a wide selection of calibration kits and regulators Industrial Scientific offers a wide selection of options necessary for necessary for optimum AirAware performance. Call for available options optimum AirAware performance. Supplies available for the AirAware for your specific configuration.
  • Page 16: Warranty

    It shall be an express condition to Industrial Scientific’s stated in writing in Industrial Scientific literature warranty that all products be carefully inspected for accompanying the product.