Address 59: Installer Code
The installer code is a 4-digit code which grants access to programming mode. The
default for this code (1234) should be changed immediately after installing the system.
Note: Do not enter Hex digits.

4.4: Periodic Test Timer Reset

The periodic test event code (address 45) is sent to the central station once every 24
hours. The first transmission of this code is sent 12 hours after power is applied to the
control panel. If a different time is required, the control panel can be programmed to
send the first periodic test message 24 hours after the periodic test timer is reset.
To reset the periodic test timer:
Press Q, 7 to enter programming mode.
1.
2.
Enter the Installer Code; the Armed LED lights up and the System LED flashes.
3.
Enter 99; the periodic test timer is reset and the periodic test code is sent to the
central station.
4.
Press # to exit programming mode.