MAINTENANCE PROCEDURES
Accumulator operation check
Before starting check operations, make sure that no person or other obstacles are in the surrounding
area.
Check nitrogen loading pressure as follows.
1. Stop the machine on a solid and flat surface.
2. Place the working tool as extended as possible (fully
extended boom and bucket in discharge position) and keep
it 1.5 m (A) away from the ground.
REMARK
Carry out the operations described in points 3-5 within 15
seconds.
Pressure in the accumulator descends gradually when the
engine is stopped. Therefore, the check must be carried out
immediately after the engine is stopped.
3. Keep the working tool at the maximum distance, turn the
start-up key to OFF and stop the engine.
4. Turn the starter key to ON.
4-70
CAUTION